Deep Learning-Based Reconstruction in Ultra-Low-Dose CT of the Ankle and Foot: A Comparative Study with Hybrid Iterative Reconstruction.
Chuluunbaatar Otgonbaatar, Jin Woo Kim, Sung-Jin Cha, Sang-Hyun Jeon, Gonchigsuren Dagvasumberel, Hackjoon Shim, Young Hwan Jang, Jhii-Hyun Ahn,
Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul 06173, Republic of Korea. · Department of Radiology, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University of Korea, Wonju 26426, Republic of Korea.
Key points
From the paper's conclusion- Objectives: To evaluate the quantitative and qualitative performance of ultra-low-dose CT with deep learning image reconstruction (DLR) compared to conventional hybrid iterative reconstruction (IR) in patients with ankle and foot fractures.
Abstract
Objectives: To evaluate the quantitative and qualitative performance of ultra-low-dose CT with deep learning image reconstruction (DLR) compared to conventional hybrid iterative reconstruction (IR) in patients with ankle and foot fractures. Methods: A total of 32 patients (mean age, 54 ± 16 years) with ankle and foot fractures were included in this retrospective study. All patients underwent ultra-low-dose CT imaging (effective dose, 0.86 ± 0.11 μSv), and the same CT raw data were reconstructed using both DLR and hybrid IR. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were quantitatively measured, and image sharpness was evaluated using a no-reference perceptual sharpness metric. Subjective image quality was assessed by a board-certified radiologist and an orthopedic surgeon using a five-point scale. Results: DLR significantly reduced image noise (47.33 ± 6.60 HU) compared to hybrid IR (87.65 ± 12.48 HU), and significantly improved SNR (31.42 ± 5.81 for DLR vs. 19.15 ± 4.48 for hybrid IR) and CNR (50.59 ± 7.62 for DLR vs. 24.08 ± 3.81 for hybrid IR). Image sharpness was significantly (p = 0.001) improved with DLR (0.76 ± 0.09) compared to hybrid IR (0.59 ± 0.09). Subjective image analysis revealed enhanced visualization of trabecular architecture, superior delineation and integrity of cortical bone, and improved depiction of bony cortical lesions with DLR compared to hybrid IR. Conclusions: Ultra-low-dose CT with DLR offers a superior approach to enhance image quality, making it a valuable tool for clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of AI-Denoised Ultra-Low-Dose CT for Detection of Acute Pelvic and Hip Fractures: A Pilot Multi-Reader Study.Diagnostics (Basel, Switzerland) · 2026
- Deep learning reconstruction for low‐dose thoracic CT of calcification inserts: A phantom study of CNR, noise magnitude, and noise textureJournal of Applied Clinical Medical Physics · 2026
- Feasibility of deep learning reconstruction algorithm combined with the "ultra triple-low" protocol at 60 kVp in CTPA: An image quality and radiation dose assessment.European journal of radiology · 2026
- Deep-learning image reconstruction algorithms for CT: A task-based image quality assessment of four CT systems using a phantomDiagnostic and Interventional Imaging · 2026
- Application of Deep Learning Algorithm-Based Image Reconstruction in Improving Abdominal CT Image Quality in Adrenal and Renal Lesions Detection.Radiology research and practice · 2026
- Deep learning reconstruction combined with contrast enhancement boost improves image quality of low-contrast-dose ctpa: a prospective randomized study.BMC medical imaging · 2026