Reducing operator-dependent variability in liver shear wave elastography through an AI-guided region-of-interest placement pipeline.
Abder-Rahman Ali, Samay Prakash, Shuhang Wang, Viksit Kumar, Peng Guo, Qian Li, Arinc Ozturk, Madeleine Sertic,
The Center of Ultrasound Research and Translation, Massachusetts General Hospital, Boston, MA, USA. aali25@mgh.harvard.edu. · The Center of Ultrasound Research and Translation, Massachusetts General Hospital, Boston, MA, USA.
Key points
From the paper's conclusion- The proposed AI-driven pipeline significantly improved ROI placement consistency and reproducibility, highlighting its potential to enhance clinical reliability in liver fibrosis assessment.
Abstract
OBJECTIVES: To develop and evaluate an artificial intelligence (AI) pipeline that automates optimal circular region-of-interest (ROI) placement and the surrounding elastogram box, provides probe-angle/contact guidance, and measures skin-to-capsule distance (SCD) to standardize liver SWE acquisition, aiming to reduce operator-dependent variability. MATERIALS AND METHODS: A two-stage pipeline combined SimCLR self-supervised pretraining on 17,441 unlabeled ultrasound images, followed by ENet fine-tuning using 495 annotated images for liver segmentation and 1564 images for poor probe contact detection. Segmentation outputs were combined with constraints on valid liver tissue pixels, axial depth, lateral boundaries, and regions of poor acoustic coupling to generate masks for optimal ROI placement. A distance transformation algorithm then identified optimal ROI coordinates within these masks. An inter-observer reader study assessed AI performance by comparing automated ROI placement, SCD measurements, and probe-angle correction guidance with annotations from expert attending radiologists. RESULTS: 18,182 US images from 654 liver elastography examinations in 609 patients (mean age, 52.6 ± 12.95 years; 55.4% male) were acquired from three ultrasound systems. The AI pipeline achieved liver segmentation performance with a Dice coefficient of 0.89, sensitivity of 0.95, specificity of 0.93, and an area under the receiver operating characteristic curve (AUC) of 0.94. The reader study demonstrated significantly higher AI-to-attending radiologist agreement (93.8%) compared to inter-attending agreement for ROI placement (81%). Cohen's kappa agreement between two attending radiologists was 0.25. CONCLUSION: The proposed AI-driven pipeline significantly improved ROI placement consistency and reproducibility, highlighting its potential to enhance clinical reliability in liver fibrosis assessment. KEY POINTS: Question Operator-dependent variability in region-of-interest (ROI) placement compromises measurement reproducibility in B-mode shear wave elastography. We developed an AI pipeline to place an optimal ROI. Findings The AI pipeline achieved liver segmentation performance of Dice 0.89 (AUC 0.94) and demonstrated higher AI-to-attending agreement (93.8%) than inter-attending agreement (81%) for ROI placement. Clinical relevance By standardizing ROI placement, elastogram box selection, and probe angle/contact guidance, the AI pipeline reduces operator-dependent variability in liver SWE acquisition, supporting more reproducible liver stiffness measurements that could improve fibrosis staging reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Defining the optimal technique for a novel EUS platform combining two-dimensional shear wave elastography and attenuation imaging: A preclinical study.Endoscopic ultrasound · 2026
- Improving shear-wave speed analysis in penile vibro-ultrasound elastography using self-supervised deep learning-based IQ denoising.Ultrasonics · 2026
- Multicenter, Multivendor Development and Validation of Automated Liver Prescription.Journal of magnetic resonance imaging : JMRI · 2026
- Quantitative Shear Wave Elastography: A Phantom—Based Comparison of Two Ultrasound SystemsBioengineering · 2026
- Effects of operator experience and measurement depth on skeletal muscle shear wave elastography.Journal of ultrasound · 2026
- Automatic Reconstruction Algorithms for In Vivo Skeletal Muscle 3D-SWEI Data.IEEE transactions on ultrasonics · 2026