Multicenter, Multivendor Development and Validation of Automated Liver Prescription.
Garrett C Fullerton, Jitka Starekova, Collin J Buelo, David T Harris, Raphael do Vale Souza, Aaron Faacks, Alexandra A Anagnostopoulos, Veronica P Christofi,
Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA. · GE HealthCare, Waukesha, Wisconsin, USA.
Key points
From the paper's conclusion- Median axial prescription IoU3D was 0.963 (interquartile range: 0.946-0.976), with median IoU3D above 0.940 for coronal and sagittal prescriptions. For axial prescriptions, margins less than 4 mm in each direction were required to achieve complete coverage of manual prescriptions in 90% of cases in the held-out test set. Effects were negligible to small across vendors, field strengths, localizer sequences, and patient factors (rrb ≤ 0.16, ε2 ≤ 0.01).
Abstract
BACKGROUND: Manual prescription of liver MRI volumes introduces inter-operator variability and prolongs exam duration. Artificial intelligence (AI)-based prescription has been demonstrated, but existing work has been limited to single-vendor settings. PURPOSE: To develop and validate an AI model for automated liver MRI prescription using a large, consecutive, multicenter dataset encompassing multiple vendors, field strengths, localizer sequences, and liver pathologies. STUDY TYPE: Retrospective. POPULATION: A total of 11,012 patients (5928 female) who underwent liver MRI exams across three vendors (GE HealthCare, Philips Healthcare, Siemens Healthineers) at three institutions, split into training/validation/test sets (70/10/20%). Liver disorders included cirrhosis, ascites, portal hypertension, and iron overload. FIELD STRENGTH/SEQUENCE: Three-plane localizers acquired using single-shot fast spin echo (68.3%) and gradient echo (31.7%) at 1.5 T (52.8%) and 3 T (47.2%). ASSESSMENT: A YOLOv8 object detection model was trained to detect the liver, torso, and arms on localizer images. Automated prescription accuracy was assessed using three-dimensional intersection-over-union (IoU3D) for axial, coronal, and sagittal prescriptions. Subgroup analyses evaluated performance across technical and patient-related factors. STATISTICAL TESTS: Mann-Whitney U tests with Bonferroni correction, Kruskal-Wallis tests, Wilcoxon signed-rank tests, Spearman correlation. Effect sizes were calculated using rank-biserial correlation (rrb) and epsilon-squared (ε2). p < 0.05 was considered statistically significant. RESULTS: Median axial prescription IoU3D was 0.963 (interquartile range: 0.946-0.976), with median IoU3D above 0.940 for coronal and sagittal prescriptions. For axial prescriptions, margins less than 4 mm in each direction were required to achieve complete coverage of manual prescriptions in 90% of cases in the held-out test set. Effects were negligible to small across vendors, field strengths, localizer sequences, and patient factors (rrb ≤ 0.16, ε2 ≤ 0.01). DATA CONCLUSION: A single multivendor model achieved accurate automated liver MRI prescription without clinically meaningful performance differences across vendors, field strengths, localizer sequences, or patient factors. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI‐Powered 3D Liver Fat Volumetric Map for Clinical‐Grade Steatosis Assessment From Cross‐Modality MRIAdvanced Intelligent Systems · 2026
- Leveraging large language models for information extraction from free-text liver MRI reports and assessment of clinical utility: a multicenter study.Quantitative imaging in medicine and surgery · 2026
- Phase-adaptive automated whole-liver quantification of signal intensity-derived liver indices from gadoxetic acid-enhanced MRI.European radiology experimental · 2026
- Clinical Implementation and Validation of Automated Slice-to-Volume Reconstruction for Fetal MRI Using a Vendor-Neutral MONAI-Based Imaging Informatics Pipeline.Journal of imaging informatics in medicine · 2026
- Large Language Models for Preoperative Microvascular Invasion Prediction in Hepatocellular Carcinoma: A Multicenter Comparison with Radiologists and Treatment Outcomes.Journal of hepatocellular carcinoma · 2026
- Robustness of radiomics-based machine learning to real-world MRI distribution shifts: a phantom study.Physics in medicine and biology · 2026