Intraoperative cone-beam CT for real-time quality control in CSF shunt surgery: a prospective workflow study.
Lina-Elisabeth Qasem, Dilara Karakaya, Christian Seemann, Nadine Angelika Döpke, Leonhard Mann, Fee Keil, Fatma Kilinç, Paul Kendlbacher,
Goethe University, University Hospital Frankfurt am Main, Department of Neurosurgery, Frankfurt am Main, Germany. · Goethe University, University Hospital Frankfurt am Main, Department of Neuroradiology, Frankfurt am Main, Germany.
Key points
From the paper's conclusion- The volumetric dose index was lower in the iCBCT group than in the control group (CBDIw median 9.27 mGy [IQR, 6.5-11.5] vs CTDIvol 31.15 mGy [IQR, 23.5-34.2]; p = 0.002). Intraoperative imaging detected catheter malposition in one VP shunt and enabled immediate revision within the same surgical session. Routine postoperative CT was omitted in all iCBCT patients, without catheter-related complications through the routine 2-3-week postoperative follow-up. OR time was longer in the iCBCT group due to image acquisition without statistical significance (median 142 min [IQR, 114-157] vs 127 min [IQR, 104-140]; p = 0.2948). Surgical time was comparable between groups (median 65.5 min [IQR, 54-80] vs 60 min [IQR, 50-76]; p = 0.590).
Abstract
INTRODUCTION: Postoperative CT is routinely performed after cerebrospinal fluid (CSF) shunt implantation to verify catheter position. Intraoperative cone-beam CT (iCBCT) enables real-time verification and may obviate routine postoperative CT. RESEARCH QUESTION: Does an iCBCT-based workflow reduce radiation exposure and permit omission of routine postoperative CT? METHODS: This interim analysis of an ongoing, prospective, observational study enrolled 10 patients undergoing ventriculoperitoneal (VP), lumboperitoneal (LP), ventriculoatrial (VA), or cyst shunt implantation with iCBCT-based quality control and compared them with a matched retrospective cohort of 10 patients managed by conventional postoperative CT. The primary endpoint was radiation exposure. Secondary endpoints were operative duration and the number of immediate revisions for catheter malposition. RESULTS: The volumetric dose index was lower in the iCBCT group than in the control group (CBDIw median 9.27 mGy [IQR, 6.5-11.5] vs CTDIvol 31.15 mGy [IQR, 23.5-34.2]; p = 0.002). Intraoperative imaging detected catheter malposition in one VP shunt and enabled immediate revision within the same surgical session. Routine postoperative CT was omitted in all iCBCT patients, without catheter-related complications through the routine 2-3-week postoperative follow-up. OR time was longer in the iCBCT group due to image acquisition without statistical significance (median 142 min [IQR, 114-157] vs 127 min [IQR, 104-140]; p = 0.2948). Surgical time was comparable between groups (median 65.5 min [IQR, 54-80] vs 60 min [IQR, 50-76]; p = 0.590). DISCUSSION AND CONCLUSION: In this interim cohort, iCBCT lowered the radiation dose index and replaced postoperative CT, enabling real-time catheter verification across CSF shunts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Angio-CT does not increase patient radiation exposure compared to conventional cone-beam CT for intra-arterial liver procedures.European radiology · 2026
- Intraoperative Cone Beam CT With One-Month Duplex Surveillance After Standard Infrarenal EVAR: A Single-Center Retrospective Cohort Study.Annals of vascular surgery · 2026
- Intraprocedural cardiac computed tomography-fluoroscopy image fusion guided structural heart intervention: a proof of concept experience during transcatheter aortic valve implantation.The international journal of cardiovascular imaging · 2026
- Image-guided same-session conversion of non-tunneled central venous catheters to implantable ports through the existing venous entry: a retrospective cohort studyFrontiers in Oncology · 2026
- Intraoperative Measurement of Internal Carotid Artery Blood Flow Using Transit-Time Flowmetry After Carotid Endarterectomy: Results from 196 Consecutive Cases.Brain sciences · 2026
- Optimization of catheter placement for interstitial gynecological brachytherapy with centroidal Voronoi tessellation.Brachytherapy · 2026