Distinguishing enhancing from non-enhancing hyperdense adnexal lesions with spectral reconstructions at photon counting CT.
Danielle Rigau, Daniel Parrott, Bhavik Bansal, Barun Bagga, Bari Dane
Department of Radiology, New York University Langone Health, New York City, USA. danielle.rigau@nyulangone.org. · Department of Radiology, New York University Langone Health, New York City, USA.
Key points
From the paper's conclusion- Attenuation change utilizing VUE images and iodine quantification can differentiate enhancing from nonenhancing hyperdense adnexal lesions at PCCT with excellent diagnostic performance. Accurate assessment of hyperdense adnexal lesion enhancement on PCCT may negate the need for follow-up imaging.
Abstract
PURPOSE: Hyperdense adnexal lesions on conventional CT often necessitate follow-up imaging. Photon counting CT (PCCT) allows for the generation of virtual unenhanced (VUE) and iodine map images. The purpose was to investigate the utility of PCCT spectral reconstructions to distinguish enhancing from nonenhancing hyperdense adnexal lesions. METHODS: A retrospective Picture Archiving and Communication System (PACS) search identified adult women with adnexal lesions on contrast-enhanced PCCT and with pelvic MRI or ultrasound within 180 days characterizing the lesion, the reference standard. Patients with adnexal lesions > 1 cm and > 20 Hounsfield Units (HU) on 70 keV PCCT images were included. Two radiologists drew region-of-interest measurements independently on adnexal lesions on thin-client software. Attenuation on VUE and 70 keV images, iodine density (ID), and iodine density normalized to aortic enhancement (NID) were recorded from the same region-of-interest. Attenuation change (ΔHU) from VUE to 70 keV was computed. Wilcoxon rank-sum test was used to compare ID, NID, and ΔHU for enhancing versus nonenhancing lesions. Receiver-operating characteristic (ROC) curves were used to determine optimal thresholds for enhancement. Inter-reader agreement was assessed with intraclass correlation coefficients (ICC). RESULTS: 38 women (median [Interquartile Range (IQR)] age: 44[37,48]) were included. 22 had nonenhancing and 16 had enhancing lesions. ΔHU for enhancing and nonenhancing lesions was 27[24,37]HU and 2[-1,5]HU, respectively (p<.001). ID of enhancing and nonenhancing lesions was 1.15[0.98,1.60] mg/ml and 0.05[-0.08,0.18] mg/ml, respectively (p<.001). NID of enhancing and nonenhancing lesions was 22[14,29]% and 1.0[-1.0,3.0]%, respectively (p<.001). The optimal ΔHU for detecting enhancement at 70 keV was 12.0HU with 100% sensitivity and 95% specificity (Area Under the Curve (AUROC) = 0.99[95% Confidence Interval (CI): 0.97,1.00]). 0.4 mg/mL ID and 8% NID both had 100% sensitivity and 95% specificity (AUROC = 0.99[95%CI: 0.97,1.00]; AUROC = 0.99[95% CI: 0.96,1.00]; respectively). ICC[95% CI] was 0.74[0.56,0.86]. CONCLUSION: Attenuation change utilizing VUE images and iodine quantification can differentiate enhancing from nonenhancing hyperdense adnexal lesions at PCCT with excellent diagnostic performance. Accurate assessment of hyperdense adnexal lesion enhancement on PCCT may negate the need for follow-up imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adnexal cyst pseudoenhancement and optimal attenuation change threshold determination at low keV reconstructions at photon counting CT.Abdominal radiology (New York) · 2026
- Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging.Insights into imaging · 2026
- Practical applications of photon-counting CT in oncology: an organ-based pictorial review.Insights into imaging · 2026
- A Pilot Study of Photon Counting CT Spectral Analysis Following Pancreatic Adenocarcinoma Resection to Differentiate Local Recurrence From Postsurgical Fibrosis.Journal of computer assisted tomography · 2026
- Optimization of spectral photon-counting CT reconstruction parameters for improved detection of peritoneal metastases compared with energy-integrating detector dual-energy CT: a phantom study.European radiology experimental · 2026
- Photon-counting Detector CT Spectral Reconstructions for Radiomics-based Liver Lesion ClassificationInvestigative Radiology · 2026