Vertical miscentering increases eye lens radiation dose and degrades image quality in pediatric head CT: insights from an in-house heterogeneous phantom.
Hamza Sekkat, Abdellah Khallouqi, Abdellah Halimi, Omar El Rhazouani, Oussama El Mouden
Université Hassan 1er, Settat, Morocco. sekkat.isss@uhp.ac.ma. · Université Hassan 1er, Settat, Morocco.
Key points
From the paper's conclusion- Miscentering of ± 1 to ± 3 cm measurably increases eye-lens dose and degrades noise-limited image quality and HU fidelity in pediatric head CT. These findings support accurate isocenter alignment as a simple but important radioprotection step in routine pediatric CT workflow. In practice, careful table-height adjustment, verification of head centering using laser or localizer guidance before acquisition, and the use of automated centering tools where available may help reduce avoidable radiation exposure while preserving image quality.
Abstract
OBJECTIVE: From a radioprotection perspective, this work aims to quantify how vertical miscentering redistributes tissue-specific dose and alters objective image quality in pediatric head CT, using a novel in-house heterogeneous pediatric head phantom, in order to better characterize avoidable positioning-related dose increases and support optimization of pediatric CT practice. METHODS: A novel pediatric head phantom incorporating validated tissue-equivalent inserts (bone, brain, CSF, eye lens and an air cavity) with machined cavities for OSLD nanodots was scanned on an 80-MDCT system using a pediatric head protocol. The phantom was positioned at isocenter (0 cm) and vertically offset by - 3, -1, + 1 and + 3 cm, each measurement was repeated three times. RESULTS: At 0 cm, mean absorbed doses were 22.93 ± 0.82 mGy (bone), 18.00 ± 0.55 mGy (brain) and 7.97 ± 0.15 mGy (eye lens). Miscentering increased dose non-uniformly and asymmetrically, with the largest sensitivity in the eye lens (10.50 ± 0.20 mGy at - 3 cm, + 31.8%; 9.37 ± 0.15 mGy at + 3 cm, + 17.6%). Noise followed a U-shaped trend, reaching a minimum at isocenter (bone ~ 23 HU at 0 cm against ~ 32 HU at - 3 cm and ~ 29 HU at + 3 cm) with corresponding SNR reduction (air ~ 125 at 0 cm against ~ 90 at - 3 cm). Low-contrast CNR (brain-CSF) peaked at isocenter (~ 5.8) and decreased under miscentering (~ 4.3 at - 3 cm; ~5.0 at + 3 cm). The largest CT-number deviations occurred in air (+ 30 HU at - 3 cm) and bone (+ 15 HU at - 3 cm). CONCLUSION: Miscentering of ± 1 to ± 3 cm measurably increases eye-lens dose and degrades noise-limited image quality and HU fidelity in pediatric head CT. These findings support accurate isocenter alignment as a simple but important radioprotection step in routine pediatric CT workflow. In practice, careful table-height adjustment, verification of head centering using laser or localizer guidance before acquisition, and the use of automated centering tools where available may help reduce avoidable radiation exposure while preserving image quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical implications of lateral head mis-centering on eye lens dose in pediatric computed tomography examinations: a phantom study.Frontiers in medicine · 2026
- Localiser-Based Software-Assisted Patient Positioning in Chest CT: A Propensity Score-Matched Study.Diagnostics (Basel, Switzerland) · 2026
- Patient Centring in CT: An International Survey of Clinical Practice and Future Directions.Journal of medical radiation sciences · 2026
- Can wide-volume CT improve pediatric head imaging? Insights from a newly fabricated anthropomorphic phantom and expert image-quality scoring.Journal of medical imaging and radiation sciences · 2026
- Evaluation of Temporal Bone Image Quality with Low-Dose Photon-Counting CT in Cadaveric Heads.AJNR. American journal of neuroradiology · 2026
- Photon-counting CT in pediatric patients: A multi-institutional evaluation of protocols and radiation exposure in 4,772 patientsDiagnostic and Interventional Imaging · 2025