AI-Assisted Compressed Sensing for Optimized Inner Ear Imaging: a Multi-Rater MRI Evaluation of CSAI T2-DRIVE.
Enrike Rosenkranz, Jennifer Köhler, Nora M Weiss, Martin Renz, Laura Leukert, Kilian Weiss, Barbara Wollenberg, Dennis M Hedderich,
Institute of Diagnostic and Interventional Neuroradiology, TUM University Hospital, Rechts der Isar Hospital, Munich, Germany. enrike.rosenkranz@tum.de. · Department of Otorhinolaryngology, Head and Neck Surgery, TUM University Hospital, Rechts der Isar Hospital, Munich, Germany.
Key points
From the paper's conclusion- AI-driven reconstruction algorithms enable statistically significant improvements in imaging of key inner-ear structures with minimal increases in scan time at 0.5 mm resolution.
Abstract
PURPOSE: High-resolution T2-weighted imaging is essential for preoperative assessment before cochlear implantation. Compressed sensing (CS) with AI-based reconstruction (CSAI) reduces acquisition times whilst preserving image quality. Although CSAI has been established in various clinical applications, its performance in inner ear imaging remains unclear. This study assesses CSAI-optimized T2-DRIVE sequences at different resolutions and acquisition times for visualizing inner ear structures. METHODS: In 30 healthy participants, CS T2-DRIVE was acquired at isotropic resolutions of 0.65, 0.5, and 0.4 mm. 0.5 and 0.4 mm datasets were also reconstructed using a commercially available AI-based reconstruction algorithm. Three raters independently assessed the imaging quality of anatomical landmarks (cochlea, semicircular canals, vestibulocochlear nerve), artifacts, and signal-to-noise ratio (SNR) using a 5-point Likert scale. Each rater re-rated a subset of images after ≥ 4 weeks. Inter- and intra-rater reliability were calculated using quadratically weighted Cohen's kappa, and differences between sequences were analyzed using cumulative link mixed models (CLMM). RESULTS: 0.4 mm isotropic imaging exhibited lower SNR compared to CSAI 0.5 mm, regardless of reconstruction algorithm (p < 0.001). Across all raters, CSAI T2 at 0.5 mm resolution significantly improved delineation of the cochlea and vestibulocochlear nerve compared to 0.65 mm imaging (p < 0.001), while assessability of semicircular canals was reduced (p = 0.082). Acquisition times increased with higher resolutions (0.65/0.5/0.4 mm: 4:02/4:25/4:34 min). CONCLUSION: AI-driven reconstruction algorithms enable statistically significant improvements in imaging of key inner-ear structures with minimal increases in scan time at 0.5 mm resolution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ai-assisted compressed sensing with deep learning reconstruction for accelerated rectal MRI: A prospective intra-individual study of image quality and preoperative staging.European journal of radiology · 2026
- PROSPECTIVE COMPARISON OF OPTIMIZED COMPRESSED SENSING AND GRAPPA-ACCELERATED 3D-TOF-MRA FOR EVALUATION OF UNTREATED INTRACRANIAL ANEURYSMS AT 1.5 T: A NON-INFERIORITY STUDYmedRxiv · 2026
- AI- assisted compressed sensing for accelerated 1.5T shoulder MRI.Technology and health care : official journal of the European Society for Engineering and Medicine · 2026
- Feasibility and image quality evaluation of accelerated T2-weighted and time-of-flight MRI using AI-assisted compressed sensing and deep reconstruction.Journal of medical imaging and radiation sciences · 2026
- Validation of Compressed Sensing Accelerated Magnetization Prepared Rapid Acquisition Gradient Echo for Fast and Reliable Brain Volume Measurement.Tomography (Ann Arbor, Mich.) · 2026
- Deep Learning-Accelerated 3D T2 CUBE MRI of the Cochlea at 1.5T and 3T: Sonic DL With AIR Recon DL Versus AIR Recon DL Alone.AJNR. American journal of neuroradiology · 2026