AI- assisted compressed sensing for accelerated 1.5T shoulder MRI.
Wenle Hu, Yizhe Wang, Hongpeng Dong, Junkai Wang, Lixue Wang, Zhongyu Chen, Zhuozhao Zheng
School of Clinical Medicine, Tsinghua University, Beijing, China. · Department of Radiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua Medicine, Tsinghua University, Beijing, China.
Key points
From the paper's conclusion- The clinical performance of AI-assisted compressed sensing (ACS) acceleration levels in 1.5-T shoulder MRI remains unclear.ObjectiveTo compare the acquisition time, image quality, and diagnostic agreement of three clinical shoulder MRI protocols using parallel imaging (PI), ACS4, and ACS8 at 1.5 T.Materials and MethodsProspectively, 158 patients with shoulder discomfort underwent three scanning pr
Abstract
BackgroundShoulder MRI has relatively long acquisition times. The clinical performance of AI-assisted compressed sensing (ACS) acceleration levels in 1.5-T shoulder MRI remains unclear.ObjectiveTo compare the acquisition time, image quality, and diagnostic agreement of three clinical shoulder MRI protocols using parallel imaging (PI), ACS4, and ACS8 at 1.5 T.Materials and MethodsProspectively, 158 patients with shoulder discomfort underwent three scanning protocols-the conventional Parallel imaging (PI) protocol, the ACS with a nominal acceleration factor of 4 (ACS4), and the ACS with a nominal acceleration factor of 8 (ACS8), covering four common sequences. Acquisition time, quantitative image quality parameters including True SNR, Relative SNR, Relative CNR, and edge rising distance (ERD), subjective image quality scores from three radiologists, and diagnostic agreement in an exploratory subgroup of 25 patients were assessed.ResultsACS4 and ACS8 reduce the total acquisition time by approximately 29% and 45%, respectively, compared with the PI protocol while maintaining comparable image quality across evaluated sequences. ACS8 generally demonstrated higher quantitative Relative SNR/CNR values in several tissues and sequences, whereas ACS4 achieved the highest True SNR and subjective image quality scores. ERD differences were not statistically significant, and diagnostic agreement was generally high across protocols.ConclusionACS protocols reduced acquisition time in 1.5-T shoulder MRI, although ACS8 compromised subjective image quality. ACS4 offered a more favorable balance between scanning efficiency and image quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ACCURACY OF COMPRESSED SENSING ACCELERATED 3D-FLAIR IN THE DIAGNOSTIC WORK-UP OF MULTIPLE SCLEROSIS AT 1.5 TmedRxiv · 2026
- Clinical evaluation of deep learning-based acquisition and reconstruction techniques for accelerated 2D shoulder magnetic resonance imaging acceleration at 3 T.Skeletal radiology · 2026
- Ai-assisted compressed sensing with deep learning reconstruction for accelerated rectal MRI: A prospective intra-individual study of image quality and preoperative staging.European journal of radiology · 2026
- Feasibility and image quality evaluation of accelerated T2-weighted and time-of-flight MRI using AI-assisted compressed sensing and deep reconstruction.Journal of medical imaging and radiation sciences · 2026
- Rapid Musculoskeletal MRI in 2026: Clinical Integration of Deep Learning ReconstructionAmerican Journal of Roentgenology · 2026
- The Current Status of AI-accelerated MRI Techniques in Clinical UseRadiology · 2025