Diagnosis of Mechanical Mitral Valve Stenosis Using Live Transoesophageal Three‐Dimensional Multivue Imaging: A Case Report
Guan Cheng, Wenhao Lu, Xiaojing Ma, Yafeng He
Key points
From the paper's conclusion- Further evaluation with live three‐dimensional transoesophageal echocardiography (3D TOE) using Philips Multivue imaging revealed restricted leaflet motion and a small irregular mass on the leaflet surface, findings suggestive of fibrotic pannus ingrowth.
Abstract
A 61‐year‐old woman presented with progressive chest tightness and dyspnoea 17 years after mechanical mitral valve replacement. Transthoracic echocardiography (TTE) showed an elevated transprosthetic velocity, raising suspicion of prosthetic valve stenosis. Further evaluation with live three‐dimensional transoesophageal echocardiography (3D TOE) using Philips Multivue imaging revealed restricted leaflet motion and a small irregular mass on the leaflet surface, findings suggestive of fibrotic pannus ingrowth. The diagnosis was confirmed intraoperatively, and the patient underwent successful redo mitral valve replacement. This case demonstrates that 3D TOE with Philips Multivue imaging can clearly visualise leaflet‐restricting pannus ingrowth without radiation and provide important clinical implications for guiding subsequent management. The technique provides added value over conventional 2D TOE and cine‐fluoroscopy, as it enables multiplanar reconstruction and en‐face views of the prosthetic valve, allowing detailed assessment of leaflet morphology and surface abnormalities that are often difficult to appreciate on 2D imaging, particularly in patients where CT is contraindicated or radiation exposure is a concern.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transcatheter Edge-to-Edge Repair of Mitral Valve Leaflet Perforation Guided by 3D Multiplanar Reconstruction Imaging.JACC. Case reports · 2026
- 3D Intracardiac Echocardiography-Guided Mitral M-TEER for a Challenging Medial P3 Flail in Patient With Esophagectomy.JACC. Case reports · 2026
- Valve-in-valve transcatheter mitral valve replacement via totally endoscopic endoclamp-assisted approach after failed bioprosthetic mitral valve: a case report.Journal of cardiothoracic surgery · 2026
- Unlocking 360° multiplane transoesophageal echocardiography for transseptal puncture guidance in mitral transcatheter edge-to-edge repairEuropean Heart Journal · 2026
- Severe Bioprosthetic Mitral Valve Dysfunction: Multimodality Imaging Identifies Structural Valve Degeneration and Guides Valve-in-Valve TMVR.JACC. Case reports · 2026
- Echocardiographic Fusion Imaging to Guide LLAMACORN and Prevent Coronary Obstruction With Self-Expanding Valve-in-Valve TAVI.JACC. Case reports · 2026