Maintaining IV Patency Throughout Pharmacokinetic Studies Through a Needle‐Free Blood Draw Device
William Naviaux, David Leinweber, Heather Barkholtz
Key points
From the paper's conclusion- These findings demonstrate the operational feasibility of needle‐free blood collection through indwelling IV catheters in a PK‐intensive research protocol conducted outside a traditional clinical research unit.
Abstract
Pharmacokinetic (PK) studies require temporally precise measurements of drug concentrations in biological matrices, most commonly whole blood or plasma. However, repeated venous sampling may increase participant burden and complicate PK‐intensive study designs. Needle‐free blood collection devices that access peripheral intravenous (IV) catheters may provide an alternative approach to repeated venipuncture while maintaining sampling schedules and specimen quality. This pilot study evaluated the feasibility of integrating the PIVO Pro needle‐free blood collection device into a PK‐intensive human laboratory study of inhaled Δ 8 ‐tetrahydrocannabinol (Δ 8 ‐THC), Δ 9 ‐THC, and placebo. Participants completed a screening visit and three dosing visits conducted in a university research facility equipped with a full‐scale driving simulator. During each dosing visit, venous blood samples were collected at nine time points over approximately 8 h through an indwelling peripheral IV catheter using the PIVO device. All participants reported that study procedures, including blood collection, were acceptable. Approximately 40% of vascular access sites required replacement, most commonly within the first hour and typically associated with poor initial blood return. Despite slower flow compared with standard venipuncture, sampling was generally sufficient to maintain the PK sampling schedule. One mild adverse event related to vascular access (localized bruising) was observed. These findings demonstrate the operational feasibility of needle‐free blood collection through indwelling IV catheters in a PK‐intensive research protocol conducted outside a traditional clinical research unit. Further studies are warranted to compare analytical performance and access durability relative to conventional venous sampling approaches.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative evaluation of three peripheral intravenous catheter designs for intensive blood sampling in Phase I clinical trials: A prospective quasi-experimental comparative study.The journal of vascular access · 2026
- Efficacy of a needle-free blood collection device (PIVO Pro) for avoiding contaminated blood culture sets in Australian emergency departments: protocol for an adaptive group sequential randomised controlled trial.BMJ open · 2026
- 39 Reduction of Serum Hemolysis in the Emergency Department Using a Needleless PIVO™(BD) Blood Collection DeviceAmerican Journal of Clinical Pathology · 2026
- A-277 Improving Sample Integrity: Preclinical Evidence Demonstrating Reduced Hemolysis with Novel Blood Collection DeviceClinical Chemistry · 2026
- An Autonomous Robotic Phlebotomy Device: Extended Analytical Validation and Real-World Hemolysis Assessment.Diagnostics (Basel, Switzerland) · 2026
- Advancing Subcutaneous Delivery: Evaluation of Near-Body Auto-Injector Systems for High-Volume Biologic Administration with Human Hyaluronidase: Poster Presented at PDA Week 2026.PDA journal of pharmaceutical science and technology · 2026