Robustness Evaluation of Physical versus Virtual Bolus for Breast VMAT Using RegGAN-Based Synthetic CT.
Yong Sang, Lingke Kong, Jianan Wu, Junqin Lei, Enzhuo Quan, Qichao Zhou
Department of Radiation Oncology National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital Chinese Academy of Medical Sciences and Peking Union Medical College Shenzhen China. · Manteia Technologies Co., Ltd, 3001-3005 Xiamen City Fujian P. R. China.
Key points
From the paper's conclusion- Using a RegGAN-based evaluation framework, this study demonstrates that although both bolus strategies are dosimetrically comparable, the virtual bolus method provides marginally improved robustness in target dose coverage against daily anatomical variations.
Abstract
BACKGROUND: Volumetric modulated arc therapy (VMAT) for breast cancer with skin involvement requires a bolus to ensure adequate surface dose. Although both physical and virtual bolus methods are clinically established, their dosimetric robustness against interfraction anatomical variations remains underexplored. This study utilized deep learning-based synthetic CT (sCT) to evaluate the robustness of these two strategies. METHODS: Ten patients with skin-involved breast cancer treated with VMAT were retrospectively analyzed. Two plans were generated for each patient: planpb (physical bolus during simulation) and planvb (virtual bolus optimization). To evaluate robustness, pretreatment cone beam CT images from fractions 1, 6, and 11 were converted to sCT using a registration-based generative adversarial network (RegGAN). Dose distributions were recalculated on these sCT to quantify deviations in the conformity index (CI), homogeneity index (HI), and volume percentage of the prescribed dose (Vpd). RESULTS: Initial planning showed no statistically significant differences between the two methods in target coverage or organs at risk sparing. In the robustness analysis performed on sCT, the virtual bolus method (planvb) demonstrated statistically superior robustness for Vpd (P < 0.05), although the absolute magnitude of improvement was small (mean Vpd deviation: -0.8% vs -1.5%). The physical bolus method (planpb) showed better robustness for CI. CONCLUSIONS: Using a RegGAN-based evaluation framework, this study demonstrates that although both bolus strategies are dosimetrically comparable, the virtual bolus method provides marginally improved robustness in target dose coverage against daily anatomical variations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Strategic planning approaches to optimize volumetric modulated arc therapy for locoregional breast irradiation.Radiation and environmental biophysics · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- From Predicted Dose to Computationally Verified Plan: An End-to-End Deep Learning and Monte Carlo Pipeline for Automated VMAT Glioblastoma Radiotherapy.Journal of imaging informatics in medicine · 2026
- Comparison of different radiotherapy planning techniques in breast cancer using active breathing coordinator.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
- Clinical implementation of deep learning-based synthetic CT for MRI-only volumetric modulated arc therapy in head and neck and pelvic cancer patientsRadiation Oncology · 2025
- Comparative Analysis of Arc Geometrical Configurations and Jaw Tracking for Peripheral Low-Dose Bath in Whole Breast VMAT.Technology in cancer research & treatment · 2026