Toward Brain Biosignature at 7 T-Repeatability of a Multiparametric CEST, QSM, QTI, and Sodium Imaging Protocol.
Annika Hofmann, Martin Freudensprung, Lion Mücke, Tobias Wilferth, Zijin Yang, Dominik Perrin, Julius Glaser, Katharina Tkotz,
Computational Imaging Lab, AIBE, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany. · Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Key points
From the paper's conclusion- Purpose To evaluate the repeatability of an extended multiparametric 7 T MRI protocol for voxel‐wise tissue characterization combining morphological, CEST, QSM, QTI, and Sodium contrasts.
Abstract
PURPOSE: To evaluate the repeatability of an extended multiparametric 7 T MRI protocol for voxel-wise tissue characterization combining morphological, CEST, QSM, QTI, and Sodium contrasts. METHODS: A repeatability study was performed in 12 volunteers without diagnosed neurological disease on a 7 T MRI system, using a comprehensive acquisition protocol with a combined acquisition time of 45:24 min, from which 45 contrast maps were derived. Quantitative repeatability was assessed using region-based and voxel-wise analyses. Precision and reliability were evaluated using the coefficient of variation (CV), repeatability coefficient (%RC), and intraclass correlation coefficient (ICC). Voxel-wise agreement between scan-rescan images was assessed using Pearson correlation coefficients. RESULTS: Across contrasts spanning morphological, CEST, QSM, QTI, and 23Na imaging, %RC was below 20% for 20 contrasts, with mean CV below 5% for most. Repeatability was highest for MP2RAGE T1 maps and QTI MD (CV ≈ 1%-2%; ICC up to 0.86) and lowest for 23Na imaging (ICC < 0.6). CEST contrasts were highly repeatable at low saturation power but more variable at higher power (CV up to ≈8%). QSM contrasts showed moderate ICC (0.46-0.82). Voxel-wise correlations exceeded r = 0.8 for most contrasts, confirming preserved spatial patterns across repeated scans. CONCLUSION: Multiparametric 7 T MRI enables reproducible voxel-wise characterization of brain tissue across a wide range of contrasts. Despite variability in specific contrasts, the overall high repeatability and strong voxel-wise agreement support the feasibility of voxel-wise imaging approaches for quantitative brain imaging and provide a foundation for future applications in clinical research and neuroscience.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- IMGP-12 Clinically Feasible QUASS-AREX CEST MRI Reduces T1-Related Variability in Pediatric Brain TumorsNeuro-Oncology · 2026
- CTP-14 Clinically Feasible QUASS-AREX CEST MRI Reduces T1-Related Variability in Pediatric Brain TumorsNeuro-Oncology · 2026
- Quasi‐Steady‐State Equilibrium CEST Reconstruction Improves T 1 ‐Normalized Apparent Exchange‐Dependent Relaxation Analysis in Brain Tumor Patients at 3 TeslaNMR in Biomedicine · 2026
- Simultaneous T1 and T2 Mapping in the Brain With QuantoRAGE: An MP2RAGE Variant Using T2-Prepared Inversion.Magnetic resonance in medicine · 2026
- Quantitative Semisolid Magnetization Transfer and Relayed Nuclear Overhauser Effect Imaging in a Multiple Sclerosis Mouse Model Using Deep Magnetic Resonance FingerprintingChemical & Biomedical Imaging · 2026
- High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) RegularizationarXiv · 2026