IMGP-12 Clinically Feasible QUASS-AREX CEST MRI Reduces T1-Related Variability in Pediatric Brain Tumors
Hahnsung Kim, Adam Goldman-Yassen, Julius Juhyun Chang, Richard Jones, Phaethon Philbrook, Natalia Revzina, Joshua Chern, Dolly Aguilera,
Key points
From the paper's conclusion- This study evaluated whether quasi-steady-state (QUASS) reconstruction of the apparent exchange-dependent relaxation (AREX) reduces T1-related variability in pediatric brain tumors.
Abstract
Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute metabolites and mobile proteins/peptides but remains sensitive to tissue T1 and the acquisition protocol in clinical settings. Pediatric brain tumors often exhibit substantial heterogeneity, which may limit the robustness of CEST MRI measurements. This study evaluated whether quasi-steady-state (QUASS) reconstruction of the apparent exchange-dependent relaxation (AREX) reduces T1-related variability in pediatric brain tumors. Pediatric brain tumor patients underwent multi-slice 3T CEST MRI using RF saturation at B1 = 0.7 μT with a saturation time of 1.5 s. Lesion regions of interest were manually defined on representative slices. Mean lesion values were calculated after exclusion of non-finite values and outlier voxels exceeding two standard deviations within each ROI. Conventional and QUASS-corrected amide (3.5 ppm) CEST metrics, including APTw, CESTR, and AREX, were evaluated. APTw was the conventional MTR asymmetry, and CESTR was defined as the difference between the fitted reference spectrum and measured Z-spectrum (CESTR = Zref − Zlab). Associations between lesion T1 and each metric were assessed using Pearson correlation and linear regression. Exploratory receiver operating characteristic (ROC) analysis was additionally performed for low- versus high-grade lesion discrimination. Routine AREX demonstrated modest association with T1 (r = -0.53, p = 0.075), whereas QUASS-reconstructed AREX demonstrated reduced and non-significant association with T1 (r = -0.30, p = 0.35). CESTR metrics showed relatively weak associations with T1 (|r| < 0.25). Across the cohort, QUASS correction reduced apparent relaxation-related variability while preserving lesion contrast. Exploratory low- versus high-grade discrimination performance was modest across metrics (AUC range: 0.54–0.69), likely limited by small cohort size and tumor heterogeneity. QUASS-reconstructed AREX reduced apparent T1-related variability in pediatric brain tumor CEST MRI. The findings support the potential clinical utility of QUASS-enhanced CEST imaging of pediatric brain tumors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CTP-14 Clinically Feasible QUASS-AREX CEST MRI Reduces T1-Related Variability in Pediatric Brain TumorsNeuro-Oncology · 2026
- Quasi‐Steady‐State Equilibrium CEST Reconstruction Improves T 1 ‐Normalized Apparent Exchange‐Dependent Relaxation Analysis in Brain Tumor Patients at 3 TeslaNMR in Biomedicine · 2026
- EP03.23 Quantitative MT and CEST MRI for Assessment of Preoperative LowGrade GliomasNeuro-Oncology · 2026
- Unleashing the potential of saturation-transfer MR fingerprinting (ST-MRF) in neuro-oncology: quantitative molecular CEST and MTC mapping.Magma (New York, N.Y.) · 2026
- Quantitative Chemical Exchange Saturation Transfer Imaging With Golden‐Angle Radial k‐Space Sampling and Locally Low‐Rank ReconstructionNMR in Biomedicine · 2026
- EP03.13 APTw-CEST MRI to visualize H3K27M diffuse midline glioma to establish a novel MRI biomarker for disease monitoringNeuro-Oncology · 2026