Neuro-Oncology

CTP-14 Clinically Feasible QUASS-AREX CEST MRI Reduces T1-Related Variability in Pediatric Brain Tumors

Hahnsung Kim, Adam Goldman-Yassen, Julius Chung, Richard Jones, Phaethon Philbrook, Dolly Aguilera, Joshua Chern, Phillip Sun

Key points

From the paper's conclusion
  • This study evaluated whether quasi-steady-state (QUASS) reconstruction of the apparent exchange-dependent relaxation (AREX) reduces T1-related variability in pediatric brain tumors.

Abstract

Background Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute metabolites and mobile proteins/peptides but remains sensitive to tissue T1 and the acquisition protocol in clinical settings. Pediatric brain tumors often exhibit substantial heterogeneity, which may limit the robustness of CEST MRI measurements. This study evaluated whether quasi-steady-state (QUASS) reconstruction of the apparent exchange-dependent relaxation (AREX) reduces T1-related variability in pediatric brain tumors. Methods and Materials Pediatric brain tumor patients underwent multi-slice 3T CEST MRI using RF saturation at B1 = 0.7 μT with a saturation time of 1.5 s. Lesion regions of interest were manually defined on representative slices. Mean lesion values were calculated after exclusion of non-finite values and outlier voxels exceeding two standard deviations within each ROI. Conventional and QUASS-corrected amide (3.5 ppm) CEST metrics, including APTw, CESTR, and AREX, were evaluated. APTw was the conventional MTR asymmetry, and CESTR was defined as the difference between the fitted reference spectrum and measured Z-spectrum (CESTR = Zref − Zlab). Associations between lesion T1 and each metric were assessed using Pearson correlation and linear regression. Exploratory receiver operating characteristic (ROC) analysis was additionally performed for low- versus high-grade lesion discrimination. Results Routine AREX demonstrated modest association with T1 (r = -0.53, p = 0.075), whereas QUASS-reconstructed AREX demonstrated reduced and non-significant association with T1 (r = -0.30, p = 0.35). CESTR metrics showed relatively weak associations with T1 (|r| < 0.25). Across the cohort, QUASS correction reduced apparent relaxation-related variability while preserving lesion contrast. Exploratory low- versus high-grade discrimination performance was modest across metrics (AUC range: 0.54–0.69), likely limited by small cohort size and tumor heterogeneity. Conclusions QUASS-reconstructed AREX reduced apparent T1-related variability in pediatric brain tumor CEST MRI. The findings support the potential clinical utility of QUASS-enhanced CEST imaging of pediatric brain tumors.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

CTP-14 Clinically Feasible QUASS-AREX CEST MRI Reduces T1-Related Variability in Pediatric Brain Tumors — Science Skim