Simultaneous T1 and T2 Mapping in the Brain With QuantoRAGE: An MP2RAGE Variant Using T2-Prepared Inversion.

Natalia Pato Montemayor, Tâm Johan Nguyên, José P Marques, Berk Can Açikgöz, Jessica A M Bastiaansen, Roland Kreis, Piotr Radojewski, Jonathan Stelter,

Swiss Innovation Hub, Siemens Healthineers International AG, Lausanne, Switzerland. · Laboratory of Computational Neuroscience, School of Computer and Communication Sciences and School of Life Sciences, EPFL, Lausanne, Switzerland.

Key points

From the paper's conclusion
  • QuantoRAGE enabled reproducible simultaneous T1 and T2 mapping at 3 T, providing an efficient framework for longitudinal and cross-sectional quantitative MRI studies and showed feasibility at 7 T.

Abstract

PURPOSE: To develop and validate a repeatable and reproducible approach, QuantoRAGE, for simultaneous whole-brain T1 and T2 mapping using adiabatic magnetization preparation. METHODS: QuantoRAGE is a 3D FLASH-based sequence using an adiabatic T2-prepared inversion followed by two readout blocks. Sequence repetitions with different preparation durations and inversion times provide T1- and T2-weighted images. Quantitative parameters are voxel-wise estimated by matching signal evolutions to a dictionary generated from extended phase graph simulations. To accelerate the method, the protocol was optimized using Cramér-Rao lower bound analysis, and a neural-network was trained on sequence-specific dictionaries for fast matching. The optimized protocol was evaluated in phantom and healthy volunteers at 3 T and compared against reference MP2RAGE T1 and multi-echo spin-echo T2 measurements. In vivo repeatability and reproducibility were quantified using scan-rescan experiments. Feasibility of QuantoRAGE at 7 T was tested in vivo. RESULTS: At 3 T, T1 and T2 phantom quantification agreed with nominal values (T1: r = 0.98, T2: r = 0.99). In eight healthy volunteers, high repeatability (bias ± SD, T1: 14.1 ± 30.2 ms, T2: 1.2 ± 1.7 ms) and reproducibility (T1: 18.9 ± 32.6 ms, T2: 1.1 ± 2.1 ms) were observed across brain regions, with T1 estimates comparable to reference methods (r = 0.96, slope = 0.74), and T2 underestimated (r = 0.79, slope = 0.44). Fast matching produced results consistent with dictionary-matching and significantly reduced parameter estimation time. At 7 T, the adiabatic preparation resulted in homogeneous T1 and T2 maps at 0.8-mm isotropic resolution. CONCLUSION: QuantoRAGE enabled reproducible simultaneous T1 and T2 mapping at 3 T, providing an efficient framework for longitudinal and cross-sectional quantitative MRI studies and showed feasibility at 7 T.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Simultaneous T1 and T2 Mapping in the Brain With QuantoRAGE: An MP2RAGE Variant Using T2-Prepared Inversion — Science Skim