A Discrete‐Time Δ‐ΔΣ Direct‐Digitization AFE With 96.1‐dB SNDR and 4‐kHz Bandwidth for Electroencephalography (EEG) Acquisition
Weixiong Tang, Cong Wei, Yuxuan Fan, Yuancheng Tang, Rongshan Wei
Key points
From the paper's conclusion- To address the challenges posed by DC electrode offset, motion artifacts, and high electrode‐skin contact impedance to the input range and conversion accuracy of analog front ends (AFEs) for electroencephalography (EEG) acquisition, this paper presents a third‐order discrete‐time Δ‐ΔΣ direct‐digitization AFE.
Abstract
To address the challenges posed by DC electrode offset, motion artifacts, and high electrode‐skin contact impedance to the input range and conversion accuracy of analog front ends (AFEs) for electroencephalography (EEG) acquisition, this paper presents a third‐order discrete‐time Δ‐ΔΣ direct‐digitization AFE. The proposed architecture employs a noninverting pseudo‐differential instrumentation amplifier, switched‐capacitor integrators, a 4‐bit successive‐approximation‐register (SAR) quantizer, and a digital accumulator (ACC). By subtracting the differential input voltages at two adjacent sampling instants, first‐order shaping of the input signal is achieved, thereby reducing the dynamic‐range (DR) requirement imposed by DC offsets and low‐frequency interference. Data‐weighted averaging (DWA) is employed to suppress unit‐mismatch errors in the multibit feedback DAC. The circuit is designed and laid out in a 180‐nm CMOS process and verified through post‐simulation. It operates at a sampling frequency of 1 MHz with a 1.8 V supply and consumes 1.07 mW. Post‐simulation results show that, with an 800‐mVpp differential input, the AFE achieves an SNDR of 96.13 dB and an SNR of 97.42 dB, and an input‐referred noise of approximately 3.8 μVrms over a 4‐kHz bandwidth. The SNDR‐based figure of merit FoM SNDR is 161.9 dB, and the system achieves a DR of approximately 100.73 dB. The input impedance is 3.367 GΩ at 100 Hz and remains 84.57 MΩ at 4 kHz. The proposed AFE achieves high conversion accuracy, a wide input range, and high input impedance, making it suitable for electroencephalography (EEG) acquisition.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Circuit Innovations for Wearable Biomedical Monitoring: CMOS Analog Front-Ends and Data Converter ArchitecturesElectronics · 2026
- A 1-kHz BW 106-dB SNDR DT Zoom ADCIEEE Transactions on Circuits & Systems II Express Briefs · 2026
- Neural implants and human safety: single-fault detection for DC-coupled recording front endsarXiv · 2026
- A 12-bit 40-MS/s Pipelined SAR ADC for Ultrasonic Nondestructive Testing ApplicationsIEEE Transactions on Instrumentation and Measurement · 2026
- Hybrid classical and deep learning preprocessing improves consistency of scalp EEG signalsDiscover Artificial Intelligence · 2026
- Comparative assessment of AD8232- and MAX30003-based ECG acquisition paths using synthetic ECG signals.Acta of bioengineering and biomechanics · 2026