Physics and imaging in radiation oncology

Linear energy transfer optimization in proton therapy of sinonasal cancer.

Miriam Paetzel, Camilla H Stokkevåg, Camilla G Boer, Jon Espen Dale, Andreas H Handeland, Kristian S Ytre-Hauge, Grete May Engeseth

Cancer Clinic, Haukeland University Hospital, Bergen, Norway. · Dept of Physics and Technology, University of Bergen, Bergen, Norway.

Key points

From the paper's conclusion
  • LET optimization significantly reduced LETdmean and RBEVAR doses to critical OOIs without compromising CTV coverage. However, its effectiveness was patient specific, with notable variability in RBEVAR D0.03cm3 doses across models, underscoring the need for individualized assessment.

Abstract

BACKGROUND: Variations in relative biological effectiveness (RBE) and linear energy transfer (LET) in proton therapy may contribute to unexpected side effects in organs of interest (OOIs). This study assessed the feasibility of LET optimization in intensity-modulated proton therapy (IMPT) for sinonasal cancer, aiming to reduce dose-averaged LET (LETd). MATERIALS AND METHODS: Robust optimized IMPT reference plans (Ref) were created for 16 patients (clinical target volume (CTV) doses: 64-70 Gy[RBE1.1]) assuming a fixed RBE = 1.1, 2 mm setup and 3.5% range uncertainties. LET optimized plans (LETopt) were generated from Ref plans using identical dose guidance, with additional LETd objectives (LETd < 3 keV/μm at ≥30 Gy[RBE1.1]) to the brainstem, chiasm and optic nerves. Plans were compared in terms of CTV coverage, OOI dose (RBE1.1), mean LETd (LETdmean) and variable RBE-weighted doses (RBEVAR). RESULTS: All Ref and LETopt plans met the CTV dose criteria. The median LETdmean across the patients was reduced in the chiasm (3.1 vs 2.3 keV/μm, P = 0.009), right optic nerve (3.1 vs 2.5 keV/μm, P = 0.016), and left optic nerve (2.7 vs 2.7 keV/μm, P = 0.023). RBEVAR doses (D0.03cm3) to OOIs were also significantly decreased, achieving patient-specific reductions from >56 Gy (RBEVAR) to below the 54 Gy (RBEVAR) threshold in the brainstem, chiasm, and optic nerves. CONCLUSIONS: LET optimization significantly reduced LETdmean and RBEVAR doses to critical OOIs without compromising CTV coverage. However, its effectiveness was patient specific, with notable variability in RBEVAR D0.03cm3 doses across models, underscoring the need for individualized assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers