Proton arc therapy reduces the dose delivered to circulating blood compared to intensity‐modulated proton therapy for head‐and‐neck cancer
Sebastian Tattenberg, Peilin Liu, Xiaoda Cong, Cornelia Hoehr, Xuanfeng Ding
Key points
From the paper's conclusion- Proton arc therapy for head‐and‐neck cancer is therefore not expected to result in higher radiation‐induced killing of circulating lymphocytes compared to IMPT.
Abstract
Background Compared to intensity‐modulated proton therapy (IMPT), proton arc therapy (PAT) has various dosimetric advantages. However, questions have been raised over whether the larger low‐dose bath during PAT may increase radiation‐induced lymphocyte killing, which is correlated with adverse clinical outcomes. Purpose The purpose of this study is to quantitatively compare radiation dose delivery to circulating blood during IMPT and PAT. Methods For each of 10 head‐and‐neck cancer patients, one IMPT and one PAT treatment plan were created, and the hematological dose (HEDOS) blood dose model was used to simulate radiation dose delivery to circulating blood. HEDOS simulations utilized gantry angle‐wise dose distributions (including for PAT) and considered gantry rotation and energy layer switching as well as irradiation times. Blood dose histograms as well as the mean dose to all simulation blood particles (D mean ) and the dose delivered to the 90% and 10% of blood particles receiving the highest dose (D 90% and D 10% ) were then compared between IMPT and PAT. Results For IMPT, blood dose metrics (in the form of mean over all patients ± one standard deviation) were (0.522 ± 0.204)Gy(RBE) for D 90% , (0.563 ± 0.212)Gy(RBE) for D mean , and (0.605 ± 0.219)Gy(RBE) for D 10% . For PAT, D 90% was (0.430 ± 0.184)Gy(RBE), D mean was (0.483 ± 0.195)Gy(RBE), and D 10% was (0.538 ± 0.207)Gy(RBE). The Wilcoxon signed‐rank test indicated statistically significant ( p < 0.05) differences between blood dose metrics of IMPT and PAT for all patients, and IMPT did not increase the percentage of blood particles which received no radiation dose during the delivery of a single treatment fraction. Conclusions Compared to IMPT, proton arc therapy was associated with significantly lower radiation dose delivery to circulating blood across a variety of different metrics. Proton arc therapy for head‐and‐neck cancer is therefore not expected to result in higher radiation‐induced killing of circulating lymphocytes compared to IMPT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A phase II randomized study of proton therapy vs intensity-modulated radiation therapy in patients with unilateral head and neck cancer.Journal of the National Cancer Institute · 2026
- Comparison of in-field secondary cancer risk based on therapeutic proton dose between proton arc therapy and intensity-modulated proton therapy in lung cancer patients.Journal of applied clinical medical physics · 2026
- Impact of anatomical changes on simulated proton arc therapy and intensity‐modulated proton therapy for lung cancerJournal of Applied Clinical Medical Physics · 2026
- Breathing-phase selection for gated proton therapy in lung cancer towards temporally targeted ultra-high dose rate delivery.Physics and imaging in radiation oncology · 2026
- A Dosimetric and Biological Comparison of Volumetric Modulated Arc Therapy and Adaptive Aperture Proton Therapy for Hippocampal-Sparing Whole-Brain Radiotherapy.Technology in cancer research & treatment · 2026
- Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcomaJournal of Applied Clinical Medical Physics · 2026