A Real-Time Low-Cost Platform for Non-Contact Respiratory Rate Monitoring: A Comparative Evaluation of RGB Optical Flow and Time-of-Flight Depth Sensing
Dominik Jasi\'owka, Patryk Ci\k{e}\.zarek, Joanna Zysnawska, Ludwin Molina Arias
Key points
From the paper's conclusion- In this work, we present a low-cost, real-time platform based on a single multimodal sensor that provides both RGB and time-of-flight (ToF) data streams, implemented on a Raspberry Pi 5 edge device.
Abstract
Respiratory rate (RR) is one of the earliest indicators of clinical deterioration, which makes its continuous measurement clinically valuable. In routine practice, however, RR is monitored almost exclusively with contact-based sensors, which require skin attachment, may alter natural breathing, and are poorly tolerated by vulnerable groups such as newborns and elderly patients. Non-contact sensing removes these constraints, with RGB video and depth imaging among its most accessible modalities. In this work, we present a low-cost, real-time platform based on a single multimodal sensor that provides both RGB and time-of-flight (ToF) data streams, implemented on a Raspberry Pi 5 edge device. The system integrates three RGB optical-flow pipelines, namely Farneb\"ack, Horn--Schunck, and Lucas--Kanade, together with a depth-based pipeline incorporating region-of-interest stabilization and distance-derived signal extraction, enabling the two modalities to be evaluated independently under the same experimental protocol. The proposed approach was evaluated on twelve healthy volunteers following a controlled protocol, including normal breathing, hyperventilation, and breath-holding, using a piezoresistive respiratory belt as a reference. RGB-based methods achieved lower RR estimation errors, with Lucas--Kanade attaining the lowest median MAE (3.83 BPM), whereas the ToF-based pipeline, although less accurate for RR estimation (median MAE 6.24 BPM), reached a higher apnea detection sensitivity (0.66 vs 0.51-0.55). These findings highlight the complementary strengths of both modalities and support their integration into unified low-cost platforms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DeepRespNet: a hybrid attention-recurrent framework for non-contact respiratory rate estimationFrontiers in Physiology · 2026
- Non-Contact SpO2 Estimation Using Camera-Based Photoplethysmography: A Machine Learning Approach on EdgeSymmetry · 2026
- Colour-Channel Selection for Video-Based Respiratory Rate Estimation: A Diagnostic Study with a Single-Shot Held-Out Evaluation.Sensors (Basel, Switzerland) · 2026
- Patient Posture-Adaptive Non-Contact Respiratory Rate Measurement Inside a Moving Ambulance Using RGB and Thermal Cameras.Diagnostics (Basel, Switzerland) · 2026
- Periodicity-Driven Adaptive Localization of Respiratory Regions for Non-Contact Respiration Monitoring in Sleeping Infants.Bioengineering (Basel, Switzerland) · 2026
- Edge-Native Non-Contact Heart Rate Monitoring via Wi-Fi CSI on Low-Cost MicrocontrollersACM Transactions on Embedded Computing Systems · 2026