Colour-Channel Selection for Video-Based Respiratory Rate Estimation: A Diagnostic Study with a Single-Shot Held-Out Evaluation.
Rinaldi Anwar Buyung, Widi Nugroho, Harum Ananda Setyawan, Muhammad Remzy Syah Ramazhan, Ahmad Ihsan Farhani
Seleris Meditekno Internasional, Graha SMI, Jl. Raya Ragunan No. 29A, Jakarta Selatan 12540, Indonesia.
Key points
From the paper's conclusion- Per-window selection lowers fusion error from 3.439 to 2.463 but stays worse than carrying a person’s last measurement forward (1.438, on 70% of rows) and no better than the blind baseline; with overlapping windows, that test is descriptive only.
Abstract
Remote respiratory-rate (RR) estimation from video is usually framed as a modelling problem and reported as one number; we treat it as a measurement problem. Using COHFACE (39 subjects, 160 clips) and VitalVideos (39 clips), both seated, we compare untrained colour channels over facial and torso regions with trained two-stream models on subject-disjoint five-fold splits, with held-out rows scored once. An untrained torso chrominance channel reaches a mean absolute error (MAE) of 1.267 breaths/min (r=+0.795), while every facial channel stays at noise level (3.69-3.91) against a 2.644 same-row blind baseline. Background patches average 4.36 and a neighbouring region 2.58, so the signal is not illumination but region-specific. Motion from sub-pixel displacement fails alone (2.92), and removing it from the colour signal does not degrade the estimate (1.156): the mechanism is narrowed, not excluded. Per-window selection lowers fusion error from 3.439 to 2.463 but stays worse than carrying a person's last measurement forward (1.438, on 70% of rows) and no better than the blind baseline; with overlapping windows, that test is descriptive only. The comparison covers the projections, regions and estimator tested here.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DeepRespNet: a hybrid attention-recurrent framework for non-contact respiratory rate estimationFrontiers in Physiology · 2026
- Quality and Similarity Indicators for Video-Based Heart Rate and Respiratory Rate Fusion: A Controlled EvaluationarXiv · 2026
- Participant-Level Cross-Fit Ensemble Disagreement for Reliability-Aware Vision-Based Infant Respiratory-Rate Estimation.Medical engineering & physics · 2026
- A Real-Time Low-Cost Platform for Non-Contact Respiratory Rate Monitoring: A Comparative Evaluation of RGB Optical Flow and Time-of-Flight Depth SensingarXiv · 2026
- SAMA: Training-Free Consensus Ridge Tracking for Camera-Based Heart Rate on Five Public DatasetsarXiv · 2026
- Contactless camera-based estimation of heart rate and variability from short facial video using remote photoplethysmography, remote ballistocardiography, and quality-aware selectionEuropean Heart Journal · 2026