Deduction of lump-sum value from breath alcohol test results.
Miroslav Hirt, František Vorel, Ľubomír Straka, František Vavera, Tomáš Vojtíšek
Key points
From the paper's conclusion- The objective of this paper is to summarise the rationales precluding the deduction of any lump-sum values (most commonly 0.24 ‰) from analytical results when ascertaining blood alcohol concentration.
Abstract
The objective of this paper is to summarise the rationales precluding the deduction of any lump-sum values (most commonly 0.24 ‰) from analytical results when ascertaining blood alcohol concentration. This work was prompted by several practical cases wherein, in the authors' opinion, the conclusions were erroneously evaluated. To avert such practices henceforth, the article analyses and synthesises pertinent methodological and legal documents, including recommendations from the specialist society, culminating in the determination that any lump-sum deductions are neither methodologically nor legally justifiable. The application of a 0.24 ‰ deduction may indeed alter the legal classification, thereby engendering erroneous conclusions. Regarding deductions from gas chromatography assay results, their inadmissibility is addressed by the Position Statement of The Czech Society for Legal Medicine and Forensic Toxicology of the Czech Medical Association of Jan Evangelista Purkyne with respect to deductions from breath test results, this is governed by the most recent case law. Both the specialist society's Position Statement and the cited jurisprudence endorse the reporting of measured values without any deductions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Determination of Alcohol in Blood by Headspace Gas Chromatography (HS-GC): A Systematic Review and Meta-Analysis.Journal of visualized experiments : JoVE · 2026
- Comparison of Breath and Blood Alcohol Elimination Rates of Non‐Alcohol Dependent People After a Heavy Drinking SessionAlcohol, Clinical and Experimental Research · 2026
- Nonadherence, Diversion, or Analytical Limitation? A Negative Urine Opiate Screen in a Patient Prescribed HydrocodoneLabMed · 2026
- Designer Benzodiazepines in Norwegian Police Casework: Blood Concentrations Related to Clinical Impairment.Journal of analytical toxicology · 2026
- A-386 Evaluation of near patient beta hydroxybutyrate testing in post mortem samples using the StatStrip analyserClinical Chemistry · 2026
- Performanz polizeilicher Cannabisvortests vor dem Hintergrund der Grenzwerterhöhung am Beispiel einer Felderprobung des Dräger DrugCheck 3000Rechtsmedizin · 2026