Determination of Alcohol in Blood by Headspace Gas Chromatography (HS-GC): A Systematic Review and Meta-Analysis.

Xue Bai, Haiji Han

People's Hospital of Kizilsu Kirgiz Autonomous Prefecture; pzpx6128@outlook.com. · People's Hospital of Kizilsu Kirgiz Autonomous Prefecture.

Meta-analysis

Key points

From the paper's conclusion
  • Headspace gas chromatography (HS-GC) with flame ionization detection (FID) or mass spectrometry (MS) is the gold standard for blood alcohol concentration (BAC) analysis in forensic and clinical toxicology.

Abstract

Headspace gas chromatography (HS-GC) with flame ionization detection (FID) or mass spectrometry (MS) is the gold standard for blood alcohol concentration (BAC) analysis in forensic and clinical toxicology. Despite widespread adoption, the comparative analytical performance of both methods across validation studies has not been quantitatively synthesized. PubMed, Scopus, Web of Science, and Google Scholar were systematically searched from database inception through May 2026. Primary outcomes were precision (%CV), accuracy (%bias), and recovery (%). Secondary outcomes included limit of detection (LOD), limit of quantification (LOQ), linearity (R2), and measurement uncertainty. Risk of bias was assessed using the adapted QUADAS-2 tool. Random-effects meta-analysis was performed using RevMan5.4. Five hundred fifty-five studies were identified, of which 17 met the inclusion criteria. Pooled intra-assay precision was 1.88%CV (95% CI: 1.12-2.65) for FID and 1.22%CV (95% CI: 0.70-1.75) for MS (p = 0.16). Inter-assay precision was 1.61%CV (95% CI: 0.83-2.39) for FID and 2.20%CV (95% CI: 1.51-2.89) for MS (p = 0.26). Pooled accuracy (%bias) was 1.94% (95% CI: 0.89-2.98) for FID and 1.73% (95% CI: 0.38-3.08) for MS. Recovery was 96.37% (95% CI: 91.89-100.84) for FID and 92.46% (95% CI: 87.14-97.78) for MS. Subgroup analysis showed significantly better precision at mid (1.35%CV) and high (1.10%CV) concentrations compared to low (2.43%CV) concentrations (p = 0.02). Both HS-GC-FID and HS-GC-MS provide analytically reliable BAC measurements within internationally accepted performance criteria. The choice between detectors may be guided by confirmation requirements and laboratory resources rather than analytical superiority.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Determination of Alcohol in Blood by Headspace Gas Chromatography (HS-GC): A Systematic Review and Meta-Analysis — Science Skim