Comparison of 3D-DXA Measurements with QCT Software Solutions for Proximal Femur Bone Density Assessment
Asier Mu\~noz, Luis del Rio, Jorge Malouf, Ludovic Humbert
Key points
From the paper's conclusion- These findings support the agreement of 3D-Shaper with independent QCT approaches and show that 3D-Shaper-QCT differences must be interpreted in light of the QCT method used.
Abstract
3D-Shaper reconstructs proximal femur shape and density in 3D from a standard hip dual-energy X-ray absorptiometry (DXA) scan. In men and women aged 35-91 years, we compared 3D-Shaper integral volumetric bone mineral density (vBMD), trabecular vBMD, and cortical surface BMD (sBMD) with quantitative computed tomography (QCT) processed with three methods: an in-house pipeline, Stradview and QCTPro CTXA, which were used to derive bone measurements equivalent to those of 3D-Shaper. Agreement, including among QCT methods, was assessed with linear regression and Bland-Altman analysis (bias and limits of agreement, LoA). 3D-Shaper agreed strongly with the in-house pipeline and Stradview for integral vBMD (R=0.95-0.96; bias 1.5 to 4.2 mg/cm$^3$; LoA $\pm$39.7 to 41.4 mg/cm$^3$), trabecular vBMD (R=0.92-0.94; bias -11.8 to -7.8 mg/cm$^3$; LoA $\pm$33.3 to 39.4 mg/cm$^3$) and cortical sBMD (R=0.94; bias 5.6 to 38.2 mg/cm$^2$; LoA $\pm$23.6 to 26.4 mg/cm$^2$). The in-house pipeline and Stradview agreed for integral vBMD (R=1.00; bias -2.7 mg/cm$^3$; LoA $\pm$3.7 mg/cm$^3$), trabecular vBMD (R=0.96-1.00; bias -0.2 to 3.9 mg/cm$^3$; LoA $\pm$6.9 to 27.5 mg/cm$^3$) and cortical sBMD (R=0.98; bias 32.7 mg/cm$^2$; LoA $\pm$14.6 mg/cm$^2$). Compared with 3D-Shaper, QCTPro CTXA integral vBMD was systematically lower (R=0.90; bias -28.4 mg/cm$^3$; LoA $\pm$61.5 mg/cm$^3$) and trabecular vBMD showed a proportional bias (R=0.89; bias -44.1 mg/cm$^3$; LoA $\pm$61.3 mg/cm$^3$). The same pattern was observed against the other QCT methods, for integral vBMD (R=0.93; bias -32.6 to -29.9 mg/cm$^3$; LoA $\pm$49.6 to 50.0 mg/cm$^3$) and trabecular vBMD (R=0.94-0.96; bias -36.3 to -32.5 mg/cm$^3$; LoA $\pm$51.2 to 54.9 mg/cm$^3$). These findings support the agreement of 3D-Shaper with independent QCT approaches and show that 3D-Shaper-QCT differences must be interpreted in light of the QCT method used.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3D-DXA cortical and trabecular parameters: agreement between hologic densitometers in clinical practice.Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry · 2026
- 3D-DXA cortical and trabecular parameters: agreement and precision between GE Healthcare Prodigy and iDXA densitometers.Archives of osteoporosis · 2026
- TP4.2 Beyond 2D Radiographs: Prospective Quantitative 3D CT Assessment of Femoral Head Coverage Influences Planning of Periacetabular Osteotomy in Developmental Dysplasia of the HipJournal of Hip Preservation Surgery · 2026
- DXA-derived three-dimensional finite element models of the femur: validation against CT-based modelsBone · 2026
- Age-related reference data for cortical and trabecular 3D-DXA parameters: the SEIOMM-3D-DXA project.Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry · 2026
- Cortical and trabecular deficits in patients with recent hip fractures assessed by DXA and 3D-DXA.Journal of bone and mineral metabolism · 2026