Directionally Supervised Neuromorphic Protection for Distribution Systems Using Local Measurements
Saurabh Prabhakar, Yubo Song, Pascal Schirmer, Bijaya Ketan Panigrahi, Subham Sahoo
Key points
From the paper's conclusion- The results establish real-time feasibility within the evaluated conditions and characterize operating-time variability across fault types and resistance levels for different network configurations.
Abstract
Reliable protection under varying power system operating conditions requires rapid fault detection while preserving selectivity against external faults and non-fault disturbances. This requirement is particularly challenging in communication-free schemes, where relays must determine trip conditions solely from local electrical measurements. To address this challenge, this paper proposes a directionally supervised neuromorphic protection scheme that integrates disturbance-responsive leaky integrate-and-fire dynamics with a direction-dependent firing threshold to distinguish internal faults from reverse-direction events. The unified relay architecture combines local disturbance detection, directional discrimination, and spike-based trip generation without requiring inter-relay communication. Its performance is evaluated under grid-connected and islanded conditions using a ring microgrid and the IEEE 13-node distribution feeder. Across 240 evaluated fault scenarios, the framework achieves median operating times of 5.4--7.6 ms across the two networks, with 78% of cases operating within 10 ms and 95% within 20 ms. It also maintains protection security during load disturbances, while fault-resistance analysis confirms its response under high-resistance faults. Controller-hardware-in-the-loop (CHIL) experiments using an RTDS simulator and an external dSPACE controller demonstrate trip-command assertion in approximately 10 ms and 5 ms for the tested single-line-to-ground and three-phase-to-ground faults, respectively. The results establish real-time feasibility within the evaluated conditions and characterize operating-time variability across fault types and resistance levels for different network configurations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transferable Neuromorphic Protection for Distribution NetworksarXiv · 2026
- Memory dendritic neural P systems for multi-ground type fault line selection in distribution networks.Neural networks : the official journal of the International Neural Network Society · 2026
- A New Current Fingerprinting Sensing Method for Adaptive Protection of PV-Integrated Distribution Networks.Sensors (Basel, Switzerland) · 2026
- Voltage-Disturbance Identification and Fast Transfer Control of an IGCT-Based Hybrid Solid-State Transfer Switch.Sensors (Basel, Switzerland) · 2026
- A transformer-configuration-aware incremental directional protection scheme for inverter-based resourcesFrontiers in Energy Research · 2026
- Scalable Reservoir Computing for Disturbance Localization and Identification in Power GridsarXiv · 2026