arXivPreprintOpen accesscond-mat.mes-hall

Matrix-aware 2D field-effect biosensing of cardiac troponin I using complementary ion-sensitive transduction

Subhabrata Das, Bharti, Babulu Pradhan, Abhishek R Nath, Kashish Sapra, Jaydeep sharma, Vijayender Bhalla, Satyaprakash Sahoo,

Key points

From the paper's conclusion
  • Here, we develop a dual-sensor platform that combines an aptamer-functionalized molybdenum disulfide (MoS2) field-effect transistor (2D-FET) with a graphene-based ion-sensitive field-effect transistor (ISFET) for the detection of cardiac troponin I (Trop-I) in complex biological matrices.

Abstract

Cardiovascular diseases remain a leading cause of mortality worldwide, highlighting the need for rapid, sensitive and reliable detection of cardiac injury at the point of care. Here, we develop a dual-sensor platform that combines an aptamer-functionalized molybdenum disulfide (MoS2) field-effect transistor (2D-FET) with a graphene-based ion-sensitive field-effect transistor (ISFET) for the detection of cardiac troponin I (Trop-I) in complex biological matrices. The atomically thin MoS2 channel enables highly sensitive detection of Trop-I, achieving a limit of detection of 0.001 ng mL-1. However, the high ionic strength of serum substantially attenuates the field-effect response, resulting in approximately 80% degradation of the sensor response. To address this matrix effect, the ISFET is employed as a secondary sensor to characterize the ionic environment of the sample. Machine-learning-assisted integration of the 2D-FET and ISFET responses is investigated as a strategy for compensating serum-induced signal distortion and recovering key electrical figures of merit extracted from the 2D-FET transfer characteristics, including maximum on-state current (Ids_max), subthreshold slope (SS) and transconductance (gm). This dual-sensor architecture combines molecular recognition, high analytical sensitivity and matrix-aware electrical signal correction, providing a potential pathway towards more reliable FET-based biomarker detection in complex biological fluids. The approach may further enable multiplexed detection of cardiac biomarkers through incorporation of target-specific aptamers, offering potential for broader assessment of cardiac stress and myocardial injury risk.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Matrix-aware 2D field-effect biosensing of cardiac troponin I using complementary ion-sensitive transduction — Science Skim