Deep learning-enhanced dual-mode multiplexed optical sensor for point-of-care diagnostics of cardiovascular diseases
Gyeo‐Re Han, Merve Eryilmaz, Artem Goncharov, Yuzhu Li, Shun Ye, Aoi Tomoeda, Emily O. Ngo, Margherita Scussat,
University of California, Los Angeles · California NanoSystems Institute
Key points
From the paper's conclusion- Here, we present a deep learning-enhanced dual-mode multiplexed vertical flow assay (xVFA) with a portable optical reader and a neural network-based quantification pipeline.
Abstract
Rapid and accessible cardiac biomarker testing is essential for the timely diagnosis and risk assessment of myocardial infarction (MI) and heart failure (HF), two interrelated conditions that frequently coexist and drive recurrent hospitalizations with high mortality. However, current laboratory and point-of-care testing systems are limited by long turnaround times, narrow dynamic ranges for the tested biomarkers, and single-analyte formats that fail to capture the complexity of cardiovascular disease. Here, we present a deep learning-enhanced dual-mode multiplexed vertical flow assay (xVFA) with a portable optical reader and a neural network-based quantification pipeline. This optical sensor integrates colorimetric and chemiluminescent detection within a single paper-based cartridge to complementarily cover a large dynamic range (spanning ~6 orders of magnitude) for both low- and high-abundance biomarkers, while maintaining quantitative accuracy. Using 50 µL of serum, the optical sensor simultaneously quantifies cardiac troponin I (cTnI), creatine kinase-MB (CK-MB), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) within 23 min. The xVFA achieves sub-pg/mL sensitivity for cTnI and sub-ng/mL sensitivity for CK-MB and NT-proBNP, spanning the clinically relevant ranges for these biomarkers. Neural network models trained and blindly tested on 92 patient serum samples yielded a robust quantification performance (Pearson's r > 0.96 vs. reference assays). By combining high sensitivity, multiplexing, and automation in a compact and cost-effective optical sensor format, the dual-mode xVFA enables rapid and quantitative cardiovascular diagnostics at the point of care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single-Probe Dual-Mode Biosensor for Cross-Validated Detection of cTnI in Myocardial Damage Evaluation.ACS sensors · 2026
- AI-driven lateral flow immunoassay for point-of-care detection of cardiac biomarkers in acute myocardial infarctionMicrochimica Acta · 2026
- Machine-learning-integrated NLRC3 and cardiac troponin T dual-analyte lateral-flow biosensor for point-of-care acute coronary syndrome screening and acute myocardial infarction-unstable angina discrimination.Mikrochimica acta · 2026
- Synchronous Visual-Photocurrent Dual-Readout for Cardiac Troponin I Sensing Enabled by Self-Powered Point-of-Care Platform.Analytical chemistry · 2026
- Cardiac troponin sensing via carbon dot-based optical biosensors: advances and clinical opportunities.RSC advances · 2026
- Highly Reliable One-Pot SERS Aptasensor for Rapid Cardiac Troponin I Detection in Acute Myocardial Infarction.ACS sensors · 2026