Characterization of a Large-Area HRPPD MCP-PMT Coupled to LYSO for TOF-PET
Yingjie Wang, Mark A. Popecki, Heejong Kim, Alexey V. Lyashenko, Stefan Cwik, Mythra Varun Nemallapudi, Jeffrey S. Souris, Michael J. Minot,
Key points
From the paper's conclusion- We characterized a 104x104 mm$^2$ HRPPD coupled to LYSO crystals and read out through a custom high-frequency amplifier.
Abstract
Large-area microchannel-plate photomultipliers (MCP-PMTs) such as the High-Rate Picosecond Photon Detector (HRPPD) are attractive for time-of-flight positron emission tomography (TOF-PET). They offer excellent single-photon time resolution, low dark count rate, and large monolithic active areas. However, the coincidence time resolution (CTR) reported so far with PET scintillators falls short of expectations based upon their single-photon time resolution. We characterized a 104x104 mm$^2$ HRPPD coupled to LYSO crystals and read out through a custom high-frequency amplifier. With a 2x2x3 mm$^3$ LYSO crystal we measured a CTR of 107 ps full width at half maximum (FWHM) against a silicon photomultiplier (SiPM)-based reference detector. After subtracting the calibrated reference detector's contribution of 42 ps, the single HRPPD detector was found to contribute 98 ps, corresponding to 139 ps for two identical HRPPD detectors in coincidence. With clinical 3x3x20 mm$^3$ crystals the CTR against the reference SiPM detector was 160 ps, corresponding to 218 ps for two identical HRPPD detectors. Timing and gain were uniform across output pads within measurement precision. Summing the four pads under a 3x3x10 mm$^3$ LYSO crystal, the energy resolution for 511 keV gamma ray was 14.6% FWHM, and the 1275 keV line of the $^{22}$Na source was within 1% of its proportional position relative to the 511 keV peak. Flood maps resolved the individual 3 mm elements of a 4x4 array despite the 25 mm pad pitch. To the best of our knowledge the observed timing resolution improves substantially on what has been reported for large-area MCP-PMTs coupled to PET scintillators, and the crystal array identification has not been demonstrated before on such a device. These results indicate that this device class deserves renewed consideration as a photodetector technology for high-performance TOF-PET systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-performance planar TOF-PET imagerJournal of Instrumentation · 2026
- High spatial resolution dual-ended readout PET detector based on continuous resistive layer silicon photomultiplier.Physics in medicine and biology · 2026
- Efficient and precise Cherenkov-based charged particle timing using SiPMsNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2026
- Design, assembly and beam validation of a full-scale TORCH moduleNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2026
- Enhanced light extraction in flex-mold nanopatterned scintillators for TOF-PET.Physics in medicine and biology · 2026
- Optical crosstalk between SiPMs in dual-ended readout.Sensors and actuators. A, Physical · 2025