Xenon energy-deposition widths in silicon: measurements and Geant4 comparisons

Andrei Azhakin, Ilya Kudryashov, Dmitry Karmanov, Igor Kovalev

Key points

From the paper's conclusion
  • We measure the central peak widths of $^{124}$Xe signals in 300- and 675-micrometre silicon layers at incident energies of approximately 152-274 MeV per nucleon and compare them with Geant4 11.4.0 electromagnetic option 4 (emopt4) and a calculation with explicit charge exchange.

Abstract

Energy-deposition fluctuations determine the isotope-separation capability of multilayer silicon detectors. We measure the central peak widths of $^{124}$Xe signals in 300- and 675-micrometre silicon layers at incident energies of approximately 152-274 MeV per nucleon and compare them with Geant4 11.4.0 electromagnetic option 4 (emopt4) and a calculation with explicit charge exchange. In the 300-micrometre detector, the emopt4 relative width of 1.844% exceeds the unselected experimental width of 1.407% by 31% and the selected width of 1.060% by 74%. For the 675-micrometre detector, selection windows around the downstream-signal peak, each approximately ten fitted first-plane standard deviations wide, give experimental upper estimates of 0.66-0.74%, compared with emopt4 predictions of 1.01-1.24%. Explicit charge-state transport gives widths of 0.889-0.932% for the thinner layer, depending on the incident charge distribution, and 0.59-0.63% for the thicker layer. These predictions are consistent with the experimental upper estimates, while emopt4 overestimates the widths for both thicknesses throughout the studied energy interval.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers