First demonstration of long-distance electron drift in liquid xenon with the Xenoscope time projection chamber
N. Angelides, M. Babicz, E. E. Barillier, L. Baudis, H. Birch, C. Capelli, J. J. Cuenca-Garc\'ia, S. George,
Key points
From the paper's conclusion- We demonstrate electron drift over $2.6$ m in liquid xenon using cosmic-muon-induced ionization signals.
Abstract
Xenoscope is a dual-phase xenon time projection chamber operated at the University of Zurich to investigate electron transport over distances relevant to the next-generation XLZD (XENON-LUX-ZEPLIN-DARWIN) observatory. We demonstrate electron drift over $2.6$ m in liquid xenon using cosmic-muon-induced ionization signals. External muon tagging provides a timing reference for charge produced at known depths, while the endpoint of the average electroluminescence waveform probes transport over the full drift length. We measure electron drift velocities of $(1.320 \pm 0.006)$ mm/$\mu$s at $(80.92 \pm 0.36)$ V/cm and $(1.436 \pm 0.001)$ mm/$\mu$s at $(96.00 \pm 0.42)$ V/cm. These results establish detectable charge transport over meter-scale distances and provide an experimental benchmark for the development of future large liquid-xenon time projection chambers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MOTION, a liquid xenon time projection chamber platform for high voltage technologies in dark matter detectorsJournal of Instrumentation · 2026
- Operating a large-diameter dual-phase liquid xenon TPC in the unshielded PANCAKE facilityThe European Physical Journal C · 2026
- Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment.The European physical journal. C, Particles and fields · 2026
- Long-term scintillation light performance, calibrations, and triggering efficiency in the MicroBooNE detectorJournal of Instrumentation · 2026
- Optical imaging in dual-phase xenon time projection chambers for neutrinoless double beta decay searchesarXiv · 2026
- ITACA revisited: ion tracking apparatus with CMOS ASICsThe European Physical Journal C · 2026