Physics-based modelling of alpha detection in ZnS(Ag) scintillation cells for radon measurements.
Miroslaw Janik, Masahiro Hosoda, Chutima Kranrod, Shinji Tokonami
National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, Japan. Electronic address: janik.miroslaw@qst.go.jp. · Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, 66-1 Hon-cho, Hirosaki-shi, Aomori-ken, Hirosaki, 036-8564, Japan; Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hon-cho, Hirosaki-shi, Aomori-ken, Hirosaki, 036-8564, Japan.
Key points
From the paper's conclusion- We present a physics-based model of alpha-particle detection in ZnS(Ag) Lucas scintillation cells for radon measurement.
Abstract
We present a physics-based model of alpha-particle detection in ZnS(Ag) Lucas scintillation cells for radon measurement. The framework combines Monte Carlo particle transport (PHITS), ion-stopping simulations (SRIM/TRIM), and Birks scintillation quenching to relate alpha-particle transport, energy deposition, and detector response. The non-spectrometric behaviour of Lucas cells is governed primarily by finite ZnS geometry and partial-energy deposition. Birks quenching further reduces the dependence of scintillation output on alpha-particle energy, particularly at large values of the Birks parameter. The model was validated experimentally in two stages. First, measurements using a fixed-geometry 241Am source confirmed the expected statistical behaviour of the counting process and identified an optimal integration time beyond which instrumental drift becomes comparable to Poisson counting noise, as determined by Allan deviation analysis. Second, radon measurements performed with Lucas-cell configurations yielded an experimental sensitivity of SLULC= 0.039, in good agreement with the PHITS-predicted intrinsic sensitivity for an effective ZnS coating thickness of approximately 15-23 μm. Sensitivity analysis showed that variations in the Birks parameter strongly affect scintillation light output and pulse-height scale, whereas the overall detector response remains dominated by alpha-particle transport and energy deposition in the ZnS layer. The model was applied to the LULC (Ludlum Lucas Cell) system, a modular replacement for legacy AB-5 counters. Calibration against AB-5 and RAD8 instruments confirmed performance parity over a radon concentration range of 900-3700 Bq m-3. An expanded uncertainty of U = 4.4% (k=2) was established, dominated by calibration transfer.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Measurement of activity size distribution of radon and thoron progeny using DRPS/DTPS based cascade impactor.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Comparative evaluation of LR115 and CR39 based Radon, Thoron and their progeny dosimeters.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A unified quenching model in Geant4 simulation for $$\alpha $$, proton and electron particles in liquid scintillator detectorsThe European Physical Journal C · 2026
- Estimation of LET distributions ofα-particles from measured scintillator-based trajectory images.Physics in medicine and biology · 2026
- Experimental Determination of Detector-Relevant Properties of ZnSe(Al,O) for Beta Spectroscopy.Sensors (Basel, Switzerland) · 2026
- Thermomechanical modelling and uncertainty reduction in cryogenic defined solid-angle alpha counting for primary Radon-222 standardisationMetrologia · 2026