Can STATCOM and UPS-Based Voltage Support Mitigate Fault-Induced Reductions in AI Data Center Grid Power Draw?
Ziang Liu, Yimeng Liu, Francis Yunhe Hou
Key points
From the paper's conclusion- This paper compares the individual and combined effectiveness of STATCOM and UPS-based voltage support in mitigating fault-induced reductions in grid power intake through electromagnetic transient simulations of a 1 GW AIDC connected to an IEEE nine-bus system.
Abstract
Artificial intelligence data centers (AIDCs) are rapidly increasing in number and capacity. These large electronic loads are interfaced through power electronic devices and can sharply reduce grid power intake during fault-induced voltage sags. Disturbances exceeding equipment ride-through capabilities may also trigger protective disconnection, posing risks to power system security. Static synchronous compensators (STATCOMs) and appropriately controlled AIDC uninterruptible power supply (UPS) rectifiers can provide reactive power support during voltage sags. This paper compares the individual and combined effectiveness of STATCOM and UPS-based voltage support in mitigating fault-induced reductions in grid power intake through electromagnetic transient simulations of a 1 GW AIDC connected to an IEEE nine-bus system. Simulation results show that STATCOM support better preserves short-term intake in milder tested faults, whereas UPS coordination maintains rectifier operation under deeper sags by reducing active intake to reserve reactive current capacity. Combined support improves auxiliary load retention and recovery in selected cases. However, severe tested sags still cause substantial grid-demand reductions even with combined support.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Low-Voltage Ride-Through in AI Data Centers via Coordinated Battery and Computing Load ControlarXiv · 2026
- Reducing Data-Center Load Transfers with Ride-Through-Aware Voltage ControlarXiv · 2026
- Comparison of Open-Source PSCAD EMT Models for Large-Scale AI Data Centers in Smart GridsarXiv · 2026
- Model-Free UPS Control Tuning for Improved Low-Voltage Ride-Through in AI Data CentersarXiv · 2026
- Using Grid-Forming Energy Storage Systems to Provide Dynamic Active Power Support for Hyperscale Data CenterIEEE Access · 2026
- Mitigating the Grid Impact of Gigawatt-Scale AI Data Centers via High-Fidelity Model FlexibilityarXiv · 2026