From the paper's conclusion- We audit a tool-grounded biometry pipeline on two separately pre-registered four-way splits of the 999 labelled HC18 images, retraining the segmenter three times on each.
Abstract
Prenatal ultrasound biometry must return a head circumference (HC) and refuse when the image cannot support one. Selective prediction trades coverage against error, but its finite-sample guarantees bound the rate of gross errors, not their magnitude. We audit a tool-grounded biometry pipeline on two separately pre-registered four-way splits of the 999 labelled HC18 images, retraining the segmenter three times on each. Calibrating the contour-completeness threshold by exact Clopper-Pearson risk control returns a certificate indistinguishable from a hand-set floor, yet the pipeline still emits a 271.3 mm error: a small, geometrically complete ring fitted to an image whose true HC is 324.6 mm. The accepted candidate scores 0.94 completeness, so the score cannot see the failure, and one outlier among $\approx 150$ answers leaves the certified risk bound ($\alpha = 0.10$) intact. A second, untouched split reproduces the mechanism on a different image (233.3 mm). Constraining the admissibility region---the anatomical range in which the measurand is defined---removes the family instead: raising the lower bound from 50 to 55 mm costs 0.4 coverage points and cuts the worst-case error on both splits to 11.4 and 11.1 mm, whereas suppressing it through the completeness threshold costs 19.0 and 12.1 points. At an anatomically defined 70 mm the frozen tests give 1.91 and 1.81 mm MAE.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Leakage-Proof Benchmark and Conformal Selective Triage for Electrohysterogram-Based Preterm Birth PredictionarXiv · 2026
- Conformal prediction for censored life history dataarXiv · 2026
- Methodological audit and empirical evaluation of a lightweight whole-volume 3D CNN for preterm brain injury classificationScientific Reports · 2026
- ReCIRC: Rectified Conformal Risk ControlarXiv · 2026
- When accuracy hides risk: risk-controlled confirmation of the critical view of safety under expert disagreementarXiv · 2026
- A critical perspective on finite sample conformal prediction theory in medical applicationsArtificial Intelligence in Medicine · 2026