When accuracy hides risk: risk-controlled confirmation of the critical view of safety under expert disagreement
Bowen Xiang, Xiao Yu, Mingze Xu
Key points
From the paper's conclusion- We propose certified confirmation, a risk-controlled monitoring rule whose threshold is selected by multiple testing so that, with probability at least 1 - {\delta}, false confirmation is at most {\alpha} overall, among disputed videos, within vendor and country groups, and before CVS is visible, using disputed labels only to calibrate.
Abstract
Automated assessment of the critical view of safety (CVS) in laparoscopic cholecystectomy has advanced rapidly, but a deployed check must decide, before the first clip, whether to confirm CVS. The standard rule calibrates a threshold so that false confirmations are rare on average. We show that this rule concentrates its errors on disputed videos, which one of three expert raters judged sufficient, and that the failure is structural. When reference labels are votes of a panel sampled from a larger expert pool, the rule that maximizes sensitivity at a fixed average false-confirmation rate also maximizes false confirmation of disputed videos, and for recognizers that recover expert judgement with less noise this rate rises with accuracy. We propose certified confirmation, a risk-controlled monitoring rule whose threshold is selected by multiple testing so that, with probability at least 1 - {\delta}, false confirmation is at most {\alpha} overall, among disputed videos, within vendor and country groups, and before CVS is visible, using disputed labels only to calibrate. In a pre-specified, hash-locked evaluation on the 300 test videos (18 countries) of the SAGES CVS Challenge, standard calibration falsely confirmed 8 of 39 disputed videos (0.21; one-sided p = 0.037 against {\alpha} = 0.10), whereas certified confirmation confirmed 2 (one-sided 95% upper bound 0.15). On development data, protection held for vendor and country groups left out of calibration. The cost was confirming 10% rather than 35% of sufficient videos on time. Average accuracy hides this risk; disputed cases must be protected explicitly.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Seeded Probes Do Not Identify a Reviewer's Miss Rate: One-Sided Misclassification in Distribution-Free Risk ControlmedRxiv · 2026
- Clinical Prediction Model Performance Metrics Cluster at Arbitrary Thresholds and are Incorrectly Reported in High-Ranking Journals: An Observational Meta-Research StudymedRxiv · 2026
- Blinded expert assessment of action acceptability in synthetic clinical outputs from local large language modelsDiscover Informatics · 2026
- An interpretable, formally verified point-of-care ultrasound risk equation for difficult videolaryngoscopy: development and internal validationmedRxiv · 2026
- Certify, Report, or Refuse: Harm-Constrained Conformal Prediction for Clinical ActionsarXiv · 2026
- Can the Remaining Answers Change the Prediction? Worst-Case Stability Checks for Personalized Rating ModelsarXiv · 2026