Methodological audit and empirical evaluation of a lightweight whole-volume 3D CNN for preterm brain injury classification
Boyu Yuan, Jiamiao Lu, Weichuan Zhang, Benqing Wu, Tuo Wang, Changshan Wang, Changming Sun, Liang Guo
Key points
From the paper's conclusion- This study uses methodological auditing to evaluate a proof-of-concept engineering pipeline for classifying radiological severity groups of preterm brain injury (BI) from T2-weighted MRI in the dHCP cohort.
Abstract
This study uses methodological auditing to evaluate a proof-of-concept engineering pipeline for classifying radiological severity groups of preterm brain injury (BI) from T2-weighted MRI in the dHCP cohort. Its primary contribution is methodology-driven empirical discovery rather than a new neural-network architecture. GloResNet combines a standard ResNet-10 backbone, MedicalNet initialization, whole-volume array resizing, mixup, and array-axis-0-reversal probability averaging, hereafter referred to as axis-0-reversal averaging; no new CNN block is proposed. The audit identifies concrete mechanisms by which small-cohort imaging results can be overstated, including unit-of-analysis drift, fold-assignment non-traceability, post hoc model-selection bias, and ranking across incompatible evaluation protocols. Building on this framework, we report the first fair, traceable comparison between a de novo trained Vision Transformer (ViT) and a domain-adapted lightweight 3D CNN on a public preterm brain injury dataset. When all sources of bias are controlled, the lightweight CNN achieves comparable or superior performance to ViT, challenging the prevailing assumption that larger, more complex architectures are always preferable in low-data regimes. Applying the audit to the historical evidence also showed that the archived GloResNet mean fold accuracy of $$69.12 \pm 7.42\%$$ was calculated over 180 scan records from 128 subjects, including repeated scans, without retained subject identifiers or out-of-fold predictions. The historical archive is therefore reported separately from the fair, traceable server-side comparison. A separate, auditable subject-level input-representation experiment did not demonstrate superiority of whole-volume input. The resulting minimum reporting standard requires an explicit statistical unit, traceable subject-level folds, retained out-of-fold predictions, prespecified selection rules, and transparent comparator conditions. These internal estimates do not establish clinical screening performance or external generalizability. The source code is available at https://github.com/ICL-SUST/GloResNet-Preterm-Brain
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross-dataset structural brain MRI quality assessment with a 25,857 parameter CNN: Capacity is not the limiting factor.Magnetic resonance imaging · 2026
- Atlas‐Augmented U‐Net Revisited: A Controlled Evaluation of Voxel‐Level Anatomical Priors for Data‐Efficient Brain Tumor SegmentationInternational Journal of Imaging Systems and Technology · 2026
- Leakage-Safe Auditing of Attribution-Driven Data Curation in Medical ImagingarXiv · 2026
- Artificial Intelligence for Neonatal Cerebral Atrophy: A Systematic Review of Deep Learning, Explainable AI, and State-Space ModelsDigital · 2026
- Automated Fetal Brain MRI Biometry in Healthy and Pathological CasesarXiv · 2026
- SFX-SwinUNETR: selective fusion and prototype-based explanation for multimodal brain tumor segmentationFrontiers in Neuroscience · 2026