Numerical Verification Limits of Asymmetric Intrastromal Hydrogel Reinforcement for Decentered Keratoconus
Juan Sumaya-Mart\'inez, Alan Altamirano-Torres
Key points
From the paper's conclusion- We reanalyze conforming two-material finite-element benchmarks and earlier optomechanical screening calculations, distinguishing solver verification from constitutive adequacy and treatment efficacy.
Abstract
Spatially tailored intrastromal hydrogel scaffolds have been proposed for decentered keratoconus, but their mechanical and optical benefits require stringent numerical validation. We reanalyze conforming two-material finite-element benchmarks and earlier optomechanical screening calculations, distinguishing solver verification from constitutive adequacy and treatment efficacy. In a curved corneal-patch benchmark with a fixed-volume rectangular inclusion, the apparent peak-displacement benefit of an offset over a centered inclusion changes from -5.66% to +1.73% across four tetrahedral meshes, while absolute displacements remain strongly mesh dependent. On the finest mesh, the quadratic term in the Green-Lagrange strain tensor contributes about 18% of the root-mean-square magnitude of the linearized strain; the underlying finite-element solutions themselves remain linear elastic. Earlier optical screening was sensitive to corneal orientation, mesh refinement and wavefront-reference conventions and is not retained as validated evidence. These observations do not establish superiority of asymmetric reinforcement. Instead, they motivate prespecified criteria for geometry-invariant finite-strain simulations, two-material interface verification, optical wavefront convergence, and independent experimental validation. No clinical recommendation is implied.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A critical review of the progress and application of finite element models in corneal biomechanics.Frontiers in bioengineering and biotechnology · 2026
- Inverse-Designed Anisotropic Intrastromal Corneal Exoskeletons for Keratoconus: A Three-Dimensional Computational Feasibility StudyarXiv · 2026
- A Concave Corneal Stromal Scaffold Based on Multi-Crosslinked GelMA Hydrogel for Delaying Keratoconus Progression and Improving corneal morphology.Acta biomaterialia · 2026
- Integration of Mechanical Testing, In Vivo Optical Coherence Elastography and Personalized Finite Element Modeling to Predict Geometrical Outcomes of Corneal Cross-LinkingAnnals of Biomedical Engineering · 2026
- Non-contact optical coherence elastography with motion-artifact correction and curvature compensation for quantitative assessment of in vivo keratoconus biomechanicsBiomedical Optics Express · 2026
- Biomechanical stabilization of the keratoconic cornea: a review of current therapeutic strategies.Frontiers in medical technology · 2026