Integration of Mechanical Testing, In Vivo Optical Coherence Elastography and Personalized Finite Element Modeling to Predict Geometrical Outcomes of Corneal Cross-Linking
Matteo Frigelli, Robert Lohmüller, Miguel A. Ariza Gracia, Günther Schlunck, Stefan J. Lang, Emílio A. Torres-Netto, Farhad Hafezi, Philippe Büchler,
University of Bern · University of Freiburg
Key points
From the paper's conclusion- We developed and calibrated a patient-specific finite element model (FEM) to predict the topographic alterations resulting from CXL and applied it to three patients with keratoconus (KC) as a proof of concept.
Abstract
PURPOSE: Corneal cross-linking (CXL) induces both mechanical and geometrical changes in the cornea, which are typically overlooked in pre-operative planning. We developed and calibrated a patient-specific finite element model (FEM) to predict the topographic alterations resulting from CXL and applied it to three patients with keratoconus (KC) as a proof of concept. METHODS: To calibrate the model, we performed nanoindentation and ex vivo optical coherence elastography (OCE) inflation tests before and after CXL on five human donor corneas. Nanoindentation results tuned the visco-hyperelastic parameters, while ex vivo OCE axial strains were used for validation. Personalized corneal models were generated from the topographies of the three KC patients, with regional stiffness in the affected areas adjusted based on axial strain measured by in vivo pressure-modulated OCE. Simulated CXL outcomes were then compared to 6-month clinical results. RESULTS: CXL induces a 16-fold increase in the fiber-related mechanical parameters and reduces the viscoelasticity time constant by three. In vivo OCE measurements showed an average mechanical weakening of 57% in the KC regions. When compared to the clinical topography at the 6-month follow-up, the CXL-induced curvature changes predicted by the model were -1.5 D vs. -1.76 D, -1.65 D vs. -1.91 D, and -1.76 D vs. -1.57 D, for the three patients, respectively. CONCLUSION: By combining FEM with in vivo corneal mechanical characterization, patient-specific topographic changes can be predicted, which has the potential to improve the planning of CXL treatments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Spatiotemporal evolution of corneal biomechanical properties after cross-linking based on optical coherence elastography.Frontiers in bioengineering and biotechnology · 2026
- A critical review of the progress and application of finite element models in corneal biomechanics.Frontiers in bioengineering and biotechnology · 2026
- Non-contact optical coherence elastography with motion-artifact correction and curvature compensation for quantitative assessment of in vivo keratoconus biomechanicsBiomedical Optics Express · 2026
- Variation in corneal biomechanical properties following continuous cross-linking treatmentEye and Vision · 2026
- Evaluating the rationale and outcomes of crosslinking corneal stromal lenticules: a systematic review with exploratory pooled analysisGraefe s Archive for Clinical and Experimental Ophthalmology · 2026
- Visual, Tomographic, and Biomechanical Outcomes of CAIRS with Accelerated Cross-Linking in Moderate to Advanced Keratoconus: A 6-Month Retrospective Case Series.Clinical ophthalmology (Auckland, N.Z.) · 2026