Sliding-scale Insulin Does Not Control Steroid-induced Hyperglycemia in a Non-diabetic Patient, No Matter How You Tune It
Nir Regev, Guy Regev
Key points
From the paper's conclusion- Here we show that endogenous regulation restores glucose with a time constant of 11.5 minutes, against 64 minutes for injected insulin to peak, so most of each dose replaces the patient's own secretion and the ordered rule moves mean glucose by less than 1.5 mg/dL.
Abstract
Sliding-scale correction insulin is the standard hospital response to high blood glucose. Its constants were derived in people who secrete no insulin, yet it is routinely ordered for patients whose own secretion is intact. We represent the correction rule as a proportional controller with a deadband, sampled four-hourly, acting on a glucose model built from published physiology, including pancreatic feedback. We derive the sensitivity of glucose to exogenous insulin, evaluate it in 4,995 virtual patients spanning published parameter ranges, and calibrate the model to a non-diabetic adolescent receiving high-dose corticosteroids and parenteral nutrition, with 45 bedside glucose measurements. Here we show that endogenous regulation restores glucose with a time constant of 11.5 minutes, against 64 minutes for injected insulin to peak, so most of each dose replaces the patient's own secretion and the ordered rule moves mean glucose by less than 1.5 mg/dL. The ordered correction factor exceeds per-unit potency in every virtual patient. Because potency falls as glucose rises, in 99.5% of virtual patients no constant correction factor is both effective at 190 mg/dL and free of overshoot at 110 mg/dL; the mismatch exceeds 25% in 79% and grows with the glucose of half-maximal secretion. Four-hour sampling is phase-locked to dextrose in medication diluents and misses the resulting excursions. When endogenous secretion is intact, the sliding scale fails for structural reasons that retuning cannot fix. A continuous insulin infusion co-delivered with the dextrose and adjusted once daily on mean glucose matches what four-hour monitoring can measure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Glargine-to-intravenous insulin dose ratio, rebound hyperglycemia and hypoglycemia after discontinuation of insulin infusion in critically ill adults: a retrospective cohort studymedRxiv · 2026
- Gluclas 2.0 - A mobile app for clinical decision support during glucose clamps.Computer methods and programs in biomedicine · 2026
- Closed-loop insulin delivery for glycaemic control in hospitalised and perioperative adults: A systematic review and meta-analysis of randomised controlled trials.Diabetes research and clinical practice · 2026
- Advanced automated insulin delivery in inpatients receiving nutritional support: a single-center, open-label, randomised controlled trialDiabetes & Metabolism · 2026
- An Evaluation of Insulin Use in Hospitalized Patients with Corticosteroid-Related Hyperglycemia.American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists · 2026
- Closed-Loop Insulin Delivery in Inpatient Care: A Systematic Review and Meta-Analysis of Clinical and Implementation Outcomes.Diabetes, obesity & metabolism · 2026