Closed-Loop Insulin Delivery in Inpatient Care: A Systematic Review and Meta-Analysis of Clinical and Implementation Outcomes.
Vaynika Gupta, Amanda Ling Jie Yee, Eleni Armeni, Kalyaani Persad, Aspasia Manta, Punith Kempegowda
College of Medicine and Health, University of Birmingham, Birmingham, UK. · Department of Applied Health Sciences, School of Health Sciences, College of Medicine and Health, University of Birmingham, Birmingham, UK.
Key points
From the paper's conclusion- This systematic review and meta‐analysis evaluated the safety, efficacy, and implementation of CL systems in inpatient care.
Abstract
AIMS: Closed-loop (CL) insulin delivery systems have transformed outpatient diabetes care. However, evidence supporting their role in inpatient settings is limited. This systematic review and meta-analysis evaluated the safety, efficacy, and implementation of CL systems in inpatient care. MATERIALS AND METHODS: This review followed PRISMA guidelines (PROSPERO: CRD420251133486). Eligible studies reported glycaemic, safety, and/or implementation outcomes for adults managed with CL systems in inpatient care. EMBASE, PubMed, MEDLINE, Scopus, CINAHL, and Cochrane Library were searched from inception to August 2026. Risk of bias was assessed using RoB2 and ROBINS-I. Random-effects meta-analysis evaluated glycaemic outcomes and length of stay (LOS). Results were presented as pooled mean differences (MDs) and 95% confidence intervals (CIs). Implementation data were analysed thematically. Intrapartum outcomes were analysed separately. RESULTS: Thirteen inpatient studies were included, nine contributing to meta-analysis. CL delivery increased time in range (MD +22.27%, 95% CI: 16.03-28.51; p < 0.001) and reduced time above range (MD -23.75%, 95% CI: -28.05 to -19.45; p < 0.001), mean glucose (MD -1.66 mmol/L, 95% CI: -2.29 to -1.03; p < 0.001) and glucose standard deviation (MD -0.64 mmol/L, 95% CI: -0.85 to -0.43; p < 0.001). No significant differences were observed in time below range, coefficient of variation or LOS. Total daily insulin dose was higher (MD +10.82 IU/day, 95% CI: 0.02-21.62; p = 0.05). No serious device-attributed adverse events were reported. Implementation challenges included staff training, technical support, and workflow integration. Four additional intrapartum studies were included; two contributed to the meta-analysis, showing increased pregnancy-specific time in range (MD +11.82%, 95% CI: 5.56-18.08; p < 0.001). CONCLUSION: CL systems improve inpatient glycaemic control, although effects on LOS and comparative safety remain uncertain. Wider adoption requires sustainable technical and organisational support.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Closed-loop insulin delivery for glycaemic control in hospitalised and perioperative adults: A systematic review and meta-analysis of randomised controlled trials.Diabetes research and clinical practice · 2026
- Intrapartum and Early Postpartum Use of Automated Insulin Delivery in Type 1 Diabetes: A Prespecified Analysis of the CIRCUIT Randomized Controlled TrialDiabetes Care · 2026
- Efficacy and safety of hybrid closed-loop systems in children aged < 7 years with type 1 diabetes: a systematic review and meta-analysis of randomized controlled trials.Pediatric diabetes · 2026
- A data-driven system for insulin pump dosing in type 2 diabetes: development, prospective evaluation and clinical applicabilitymedRxiv · 2026
- Advanced automated insulin delivery in inpatients receiving nutritional support: a single-center, open-label, randomised controlled trialDiabetes & Metabolism · 2026
- Artificial Pancreas and Closed-Loop Insulin Delivery: From Early Concepts to AI-Driven Diabetes Automation.Biosensors · 2026