VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC-Metal Benchmark
Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique
Key points
From the paper's conclusion- We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only.
Abstract
Metal artifacts in postoperative musculoskeletal CT obscure bone-implant and adjacent soft-tissue interfaces. Many metal artifact reduction (MAR) methods require unavailable raw projections or learned models that may shift across scanners and implants. We present VoxelSynth3D, a training-free 3D image-domain framework for reconstructed CT. The framework combines support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only. The operating point was fixed in a near-flat validation basin. With exact-mask oracle localization, all methods share a metal-excluded tissue ROI. On 40 held-out cases, VoxelSynth3D reduced RMSE from 801.48 to 786.18 HU (paired gain 15.30 HU, 95% CI 11.68-19.23), improving every case and exceeding the evaluated 3D Gaussian smoother by 13.58 HU. Clean-edge agreement decreased next to metal but exceeded input beyond 5 mm. Thus, VoxelSynth3D provides case-consistent within-distribution tissue-error reduction with a localized structural tradeoff. Spacing-aware sensitivity retained aggregate broad-region improvement and identified near-metal calibration as a target.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Unsupervised CT Metal Artifact Reduction Via Consistent Artifact Modeling.IEEE journal of biomedical and health informatics · 2026
- A hybrid training database and evaluation benchmark for assessing metal artifact reduction methods for X‐ray CT imagingMedical Physics · 2025
- PDDUNet: A primal-dual deep unrolling network for CT metal artifact reduction.Journal of X-ray science and technology · 2026
- DuF-DiT: Dual-Domain Fusion Diffusion Transformer with Latent Conditional Modeling for CT Metal Artifact Reduction.Medical engineering & physics · 2026
- Conditional flow matching framework for metal artifact reduction in head-and-neck radiotherapy planning CTScientific Reports · 2026
- Path-length-aware sinogram completion via direct moment enforcement for metal artifact reduction in X-ray CT.Biomedical physics & engineering express · 2026