Conditional flow matching framework for metal artifact reduction in head-and-neck radiotherapy planning CT
Chungil Lee, Younghoon Jeon, Jaewon Song, Jongin Oh, Jaehyeok Seo, Mina Yu, Kwan-Woo Lee
Key points
From the paper's conclusion- We present a conditional flow-matching framework for image-domain metal artifact reduction (CFM-MAR) in head-and-neck CT, compared with linear-interpolation MAR (LI-MAR) and normalized MAR (NMAR).
Abstract
We present a conditional flow-matching framework for image-domain metal artifact reduction (CFM-MAR) in head-and-neck CT, compared with linear-interpolation MAR (LI-MAR) and normalized MAR (NMAR). Trained on the public AAPM CT-MAR head subset (1,626 slices), CFM-MAR reduced patient-region root-mean-square error (RMSE) on the slice-level test set from 228.1 to 44.5 ± 23.0 Hounsfield units (HU), against 53.0 ± 72.5 HU for NMAR and 75.1 HU for LI-MAR. Per slice, CFM-MAR and NMAR were not significantly different ( p = 0.14); the lower mean was driven by a shorter error tail: no slice was worse than no correction and the worst slice reached 172 HU, against four worsened slices and a maximum RMSE of 854 HU for NMAR. Under leave-one-examination-out training, mean RMSE increased to 64.1 HU, exceeding NMAR (56.2 HU), while the tail advantage persisted. On 50 clinical planning CTs CFM-MAR suppressed streaks but partially filled internal air cavities. Blinded readers preferred its output to that of a matched direct-regression network with lower benchmark distortion, including for contouring. These findings are based solely on imaging measurements; dosimetric analysis, contouring validation, workflow validation and external HU validation remain to be performed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A hybrid training database and evaluation benchmark for assessing metal artifact reduction methods for X‐ray CT imagingMedical Physics · 2025
- VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC-Metal BenchmarkarXiv · 2026
- From synthesis to clinic: a task-specific framework for CT images metal artifact reduction in cervical brachytherapy.Radiation oncology (London, England) · 2026
- Unsupervised CT Metal Artifact Reduction Via Consistent Artifact Modeling.IEEE journal of biomedical and health informatics · 2026
- Image-Domain CT Metal Artifact Reduction Using an Endpoint-Conditioned Diffusion Bridge.ArXiv · 2026
- PDDUNet: A primal-dual deep unrolling network for CT metal artifact reduction.Journal of X-ray science and technology · 2026