DuF-DiT: Dual-Domain Fusion Diffusion Transformer with Latent Conditional Modeling for CT Metal Artifact Reduction.
Yiling Gong, Siyu Yang, Meng You, Wei Tang, Jixiang Guo
Sichuan University College of Computer Science, No. 24, South Section 1, Yihuan Road, Chengdu, 610065, China. · College of Computer Science, Sichuan University, No. 24, South Section 1, Yihuan Road, Chengdu, 610065, China.
Key points
From the paper's conclusion- Ablation studies supported the complementary contributions of adaptive conditioning and bidirectional cross-domain interaction.
Conclusions: The results support sustained dual-domain interaction in latent space as an effective strategy for CT metal artifact reduction, with favorable image fidelity, CT-value accuracy, and downstream bone-segmentation performance under the evaluated conditions.
Abstract
Metal implants introduce nonlinear corruptions into computed tomography (CT) projection measurements, producing severe artifacts in reconstructed images. Dual-domain metal artifact reduction (MAR) methods combine sinogram and image information to correct corrupted projections and suppress image-domain artifacts. However, their cross-domain communication commonly relies on predefined projection operations or fixed interaction pathways. In diffusion-based MAR, sustained interaction between evolving image and sinogram representations throughout the denoising process remains insufficiently explored. Methods: We introduce the Dual-Domain Fusion Diffusion Transformer (DuF-DiT), which iteratively fuses parallel image and sinogram latent representations during denoising. Its Dual-Domain Fusion Transformer blocks combine intra-domain self-attention with bidirectional cross-attention. A difference-guided gating mechanism adaptively blends conditions from metal-affected observations and linear-interpolation (LI) priors. Denoising in a CT-adaptive latent space further reduces the computational cost of the two parallel streams. Results: On synthesized DeepLesion data, DuF-DiT achieved the highest mean structural similarity index (SSIM), competitive peak signal-to-noise ratio (PSNR) and root mean square error (RMSE), and the lowest mean absolute error (MAE) in Hounsfield units (HU), with a small mean HU bias. It also achieved the lowest Fréchet Inception Distance (FID) among the compared methods. On clinical CT data, qualitative comparisons showed reduced visible artifacts with preserved anatomical structures, while DuF-DiT yielded the numerically highest mean bone-segmentation Dice coefficient on CLINIC-metal. Ablation studies supported the complementary contributions of adaptive conditioning and bidirectional cross-domain interaction. Conclusions: The results support sustained dual-domain interaction in latent space as an effective strategy for CT metal artifact reduction, with favorable image fidelity, CT-value accuracy, and downstream bone-segmentation performance under the evaluated conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Unsupervised CT Metal Artifact Reduction Via Consistent Artifact Modeling.IEEE journal of biomedical and health informatics · 2026
- Image-Domain CT Metal Artifact Reduction Using an Endpoint-Conditioned Diffusion Bridge.ArXiv · 2026
- PDDUNet: A primal-dual deep unrolling network for CT metal artifact reduction.Journal of X-ray science and technology · 2026
- A hybrid training database and evaluation benchmark for assessing metal artifact reduction methods for X‐ray CT imagingMedical Physics · 2025
- VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC-Metal BenchmarkarXiv · 2026
- DuDoTransGAN: Dual-Domain transformer based generative adversarial unsupervised network for metal artifact reduction in paired and unpaired CT.European journal of radiology · 2026