Targeting Sample Reception Errors: A Failure Reporting Analysis and Corrective Action System (FRACAS)-Based Laboratory Quality Improvement Study.
Vijetha Shenoy Belle, Merin K Thomas, Nihaal Maripini, Saritha Kamath U
Department of Biochemistry, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India. · Department of Medical Laboratory Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India.
Key points
From the paper's conclusion- FRACAS-guided interventions reduce pre-examination NCs and lower RPNs for high-risk processes, supporting their use for pre-examination quality improvement.
Abstract
INTRODUCTION: Approximately 70% of clinical decisions depend on laboratory test results, underscoring the critical importance of examination accuracy. Among the phases of the total testing process, the pre-examination phase accounts for the highest proportion of errors; therefore, interventions aimed at reducing these errors can significantly enhance overall laboratory quality. This study aims to evaluate the effectiveness of risk assessment and corrective strategies through the implementation of the Failure Reporting, Analysis, and Corrective Action System (FRACAS) by comparing Risk Priority Number (RPN) scores before and after implementing corrective strategies. METHODOLOGY: This retrospective observational quality-improvement study obtained approval from the institutional ethics committee. It analyzed two years of data from a clinical biochemistry laboratory. A total of 573 samples were rejected in a NABL-accredited, ISO 15189-compliant tertiary-care hospital in South India. Each nonconformance (NC) was categorized, and its frequency, percentage distribution, and RPN were calculated for both study periods. The effectiveness of risk assessment and corrective strategies was evaluated by comparing pre- and post-corrective RPN values and percentage reductions in NCs. RESULTS: Data from 573 rejected samples (216 pre-corrective in 2021; 357 post-correctives in 2022) were analysed. Mean RPN decreased from 18.0 ± 16.1 to 10.9 ± 15.3 (mean difference 6.0, 95% CI 2.0-24.0, p = 0.041); paired Bayesian t-test showed BF10 = 1.15, evidence for effectiveness. Four NCs were eliminated; however, three new NCs emerged post-STAT lab launch. CONCLUSION: FRACAS-guided interventions reduce pre-examination NCs and lower RPNs for high-risk processes, supporting their use for pre-examination quality improvement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Spectrum of Preanalytical Laboratory Errors in Clinical Biochemistry Laboratory in a Tertiary Care Center in Nepal.Kathmandu University medical journal (KUMJ) · 2025
- Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026
- Partitioning All-Cause Pre-Analytical Laboratory Rejections: A 25-Month Retrospective Audit of Specimen Quality Failures with Six Sigma, IFCC, and Pareto Analysis.Journal of clinical medicine · 2026
- Pre-Analytical Errors Before, During, and After the COVID-19 Pandemic: A Multi-Year Retrospective Observational Study.Healthcare (Basel, Switzerland) · 2026
- Improving Diagnostic Turnaround Time and Analytical Reliability in Clinical Biochemistry Laboratories: A Quality Management FrameworkInternational Journal of Latest Technology in Engineering Management & Applied Science · 2026
- B-043 Comparison of Turnaround Time of Beckman Coulter Power Processor and DxA 5000 Automated SystemsClinical Chemistry · 2026