Partitioning All-Cause Pre-Analytical Laboratory Rejections: A 25-Month Retrospective Audit of Specimen Quality Failures with Six Sigma, IFCC, and Pareto Analysis.
Shoukat Ali Arain, Abdullah Naji Alhawil, Shahid Akhtar Akhund, Mahnoor Ali, Salman Aldosari, Abdulwahab Z Binjomah
Department of Pathology, College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia. · College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia.
Key points
From the paper's conclusion- We mapped Specimen Quality Failure causes into IFCC WG-LEPS Quality Indicators (QIs) and evaluated via Six Sigma metrics, IFCC benchmarks, and Pareto analysis—stratified by laboratory section, sample type, priority, and work shift.
Abstract
Objectives: Aggregate pre-analytical rejection rates conflate specimen-quality failures and administrative events, which require distinct mitigation protocols. We disaggregated rejection events to isolate specimen-quality failures and benchmarked them against global frameworks. Methods: We conducted a 25-month retrospective audit (July 2023 to August 2025) of test orders received by the Al Rass General Hospital laboratory. Using an AI-assisted classification protocol, we isolated pre-analytical Specimen Quality Failures from operational and administrative events. We mapped Specimen Quality Failure causes into IFCC WG-LEPS Quality Indicators (QIs) and evaluated via Six Sigma metrics, IFCC benchmarks, and Pareto analysis-stratified by laboratory section, sample type, priority, and work shift. Results: Of 905,018 test orders received, 35,476 were rejected (overall rejection rate 3.92%). However, the specimen-quality failures were 2.21% (σ = 3.51), with 15,495 entries excluded as operational events. Clotted samples (26.2%), hemolysis (23.0%), wrong sample type (20.2%), sample not received (7.8%), and insufficient volume (7.1%) together accounted for 84.3% of specimen quality failures (the Vital Few). Most individual categories scored Good (≥4.0) on Sigma, despite a pooled Sigma of 3.51 (Acceptable). Benchmarking against IFCC WG-LEPS targets showed that 6 of 13 quality indicators, including clotted sample, wrong sample type, and insufficient volume, fell Below Minimum, demonstrating divergent absolute internal process capability metrics and population-relative external benchmark performance signals. STAT samples had a lower specimen quality failure rate than Routine samples (1.25% vs. 2.51%). Although the morning shift accounted for 80.98% of total rejections, only 53.4% represented true specimen quality failures. Conclusions: Headline laboratory rejection rates are inflated by operational and administrative events, necessitating partitioned reporting models. While individual Westgard Sigma scores demonstrate satisfactory absolute process capability across most specimen quality failure categories, cross-referencing against population-relative IFCC targets contextualizes these results and identifies areas performing in the lower international quartiles. Quality improvement strategies require structural changes and workforce training.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026
- Establishing denominator-consistent Six Sigma benchmarks for venous blood specimen rejection: a multi-center retrospective quality-indicator study using 21 million specimens in Western China.Frontiers in medicine · 2026
- Spectrum of Preanalytical Laboratory Errors in Clinical Biochemistry Laboratory in a Tertiary Care Center in Nepal.Kathmandu University medical journal (KUMJ) · 2025
- A-306 Prevalence, Causes, and Mitigation Strategies for Pre-analytical Errors Occurring at The University Hospital of the West Indies Chemistry LaboratoryClinical Chemistry · 2026
- Quality Indicator-Driven Six Sigma Scale Assessment of Extra-Analytical Phases in Clinical Chemistry Laboratory-Insights from a Tertiary Care Hospital.Annals of clinical biochemistry · 2026
- Simulation Study on Preanalytical Variables in Coagulation Testing: Interference Effects and Threshold Determination of Hemolysis, Lipemia, Icterus and Insufficient Sample Volume.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2026