Archiving of Cardiac Catheterization Laboratory Procedures and Records of Radiation Exposure: A Single-Center Experience.
Pranab Jyoti Bhattacharyya, Maitreyee Bhattacharyya, Jahir Alam Choudhury
Cardiology, Cardiothoracic and Neurosciences Centre, Gauhati Medical College and Hospital, Guwahati, IND. · Cardiac Care Technology, Gauhati Medical College and Hospital, Guwahati, IND.
Key points
From the paper's conclusion- Background and objective Cardiac catheterization laboratories (Cath Labs) increasingly perform fluoroscopy-guided diagnostic and interventional procedures, making systematic monitoring of radiation exposure important.
Abstract
Background and objective Cardiac catheterization laboratories (Cath Labs) increasingly perform fluoroscopy-guided diagnostic and interventional procedures, making systematic monitoring of radiation exposure important. Structured archiving can support radiation surveillance, quality assurance, and procedural evaluation. This study aimed to examine dose-area product/kerma-area product (DAP/KAP), cumulative air kerma (CAK/Ka,r), and fluoroscopy time, with particular attention to variation by procedure type and the influence of BMI. Methods A hospital-based retrospective cohort study was conducted at the Cardiac Catheterization Laboratory of Gauhati Medical College and Hospital. A total of 190 archived patient records were analyzed. Demographic variables, procedure category, fluoroscopy time, DAP/KAP, and CAK were evaluated. The association between BMI and radiation exposure was also examined. Results The mean age of the cohort was 55.88 ± 11.04 years and mean BMI was 26.78 ± 3.87 kg/m². Coronary angiography (CAG) + percutaneous transluminal coronary angioplasty (PTCA) was the most frequently performed procedure (70.5%). Median DAP/KAP and CAK were lowest for diagnostic CAG and substantially higher for CAG + PTCA. The median fluoroscopy time was 1.9 minutes for CAG, 8.3 minutes for CAG + PTCA, and 13.1 minutes for other procedures. BMI demonstrated a significant positive correlation with DAP/KAP (r = 0.470, p < 0.001) and CAK (r = 0.469, p < 0.001). DAP/KAP and CAK demonstrated a very strong positive correlation (r = 0.941, p < 0.001). No radiation-related complications or dose alerts were documented. Conclusions Radiation exposure varied by procedure type and BMI. Systematic Cath Lab archiving and continuous monitoring of DAP/KAP, CAK, and fluoroscopy time can provide useful baseline data for radiation safety, quality assurance, and dose optimization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Obesity as a determinant of radiation burden in the cardiac catheterization laboratory.Cardiovascular revascularization medicine : including molecular interventions · 2026
- Identifying High-Dose Views and Modes in the Catheterization Laboratory: A Run-Level Mixed-Effects Analysis.Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2026
- Radiation Exposure in Elective Endovascular Carotid Artery Stenting.Clinical neuroradiology · 2026
- Determinants of Radiation Exposure and Radiation Overexposure During Percutaneous Coronary Intervention. A Real-World Study of 10,634 Procedures With Development of a Pragmatic Radiation-Alert Risk ScoremedRxiv · 2026
- Real-time Radiation Exposure Monitoring in the Cardiac Catheterization Laboratory Using a Digital RRPD Dosimeter.Health physics · 2026
- Effective Dose Evaluation of Cerebral Angiography Using Kerma Area Product and Development of Effective Dose Conversion Factors.Diagnostics (Basel, Switzerland) · 2026