Severe Hypercapnia and Hemodynamic Instability During Carbon Dioxide Insufflation During Robot-Assisted Thoracic Surgery.

Mototsugu Watanabe, Noriaki Shiraha, Yoshinobu Shikatani, Kenji Uehara

Thoracic Surgery, National Hospital Organization Iwakuni Clinical Center, Iwakuni, JPN. · Anesthesia, National Hospital Organization Iwakuni Clinical Center, Iwakuni, JPN.

Case report

Key points

From the paper's conclusion
  • We report a case examining the severity and time course of CO2-induced hypercapnia during capnothorax-assisted robot-assisted thoracoscopic surgery (RATS).

Abstract

The carbon dioxide (CO2) insufflation system enhances robot-assisted thoracoscopic surgery (RATS) by maintaining a stable capnothorax and facilitating smoke evacuation. However, CO2 insufflation can cause hypercapnia and hemodynamic instability, requiring vigilant monitoring. We report a case examining the severity and time course of CO2-induced hypercapnia during capnothorax-assisted robot-assisted thoracoscopic surgery (RATS). A 68-year-old obese man underwent robot-assisted lung resection with capnothorax, resulting in elevated CO2 levels that caused atrial fibrillation and hypotension. Blood gas analysis showed severe acidosis and hypercapnia. Following discontinuation of the capnothorax, hypercapnia improved within 37 minutes. The surgery was completed successfully without capnothorax, and the patient was discharged on postoperative day 6 without complications. While CO2 insufflation supports minimally invasive surgery, this case documents an extreme hypercapnic event with an arterial partial pressure of carbon dioxide (PaCO2) of 110 mmHg with rapid cardiovascular compromise in a high-risk patient using the capnothorax system, underscoring the need for vigilant monitoring, even with advanced insufflation technology.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers