Arterial-to-End-Tidal CO₂ Gradient Direction as a Differential Diagnostic Clue During Sudden Hypercapnia in Thoracoscopic Surgery with Capnothorax: A Report of 2 Cases.
Yumi Nakao, Urara Hirano, Natsuki Anada, Risa Sakuma, Atsuhiro Kitaura, Hiroatsu Sakamoto, Haruyuki Yuasa, Yasufumi Nakajima,
Department of Anesthesiology and Intensive Care, Kindai University Faculty of Medicine, Osaka, Japan.
Key points
From the paper's conclusion- We report 2 contrasting cases in which the direction of the arterial-to-end-tidal CO₂ gradient, Δ(PaCO₂-EtCO₂), guided differential diagnosis.
Abstract
BACKGROUND During minimally invasive thoracic surgery with intrathoracic carbon dioxide (CO₂) insufflation, an abrupt rise in end-tidal CO₂ (EtCO₂) alone cannot distinguish true hypercapnia from artifactual or exogenous CO₂ contamination. We report 2 contrasting cases in which the direction of the arterial-to-end-tidal CO₂ gradient, Δ(PaCO₂-EtCO₂), guided differential diagnosis. CASE REPORT Case 1: A 62-year-old man undergoing robot-assisted right lower lobectomy developed an abrupt EtCO₂ rise from 40 to 130 mm Hg immediately after CO2 insufflation, with severe hypotension and bradycardia. Arterial blood gas (ABG) analysis showed pH 6.79, PaCO2 228.0 mm Hg, and Δ(PaCO₂-EtCO₂) +98.0 mm Hg, suggesting a possible contribution of low cardiac output to the widened gradient. Insufflation was stopped, 2-lung ventilation resumed, and surgery completed without re-insufflation. Case 2: A 77-year-old man undergoing thoracoscopic subtotal esophagectomy developed an EtCO₂ rise from 54 to 99 mm Hg while hemodynamically stable. After excluding circuit and sampling-line artifacts, ABG analysis showed pH 7.21, PaCO₂ 72.5 mm Hg, and Δ(PaCO₂-EtCO₂) -26.5 mm Hg, suggesting exogenous CO₂ contamination of expiratory gas rather than systemic retention alone. Surgical exploration confirmed a partial injury to the left main bronchus. CONCLUSIONS During abrupt EtCO₂ surges under 1-lung ventilation with capnothorax, the direction of Δ(PaCO₂-EtCO₂) on prompt ABG analysis may help prioritize the differential diagnosis between systemic retention and exogenous contamination, provided hemodynamics and circuit integrity are concurrently assessed. A markedly positive gradient during shock may indicate systemic CO₂ loading with reduced pulmonary perfusion, whereas a negative gradient after artifact exclusion suggests pleuro-airway communication or peri-device leakage. This hypothesis-generating approach remains unvalidated as a standalone diagnostic tool.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Higher intraoperative arterial-to-end-tidal carbon dioxide gradients are associated with postoperative respiratory morbidity after lung cancer resection: a retrospective INSPIRE cohort study.Frontiers in medicine · 2026
- Cardiorespiratory responses to head-down tilt: an investigation of the arterial-endtidal PCO₂ difference.Respiratory physiology & neurobiology · 2026
- Severe Hypercapnia and Hemodynamic Instability During Carbon Dioxide Insufflation During Robot-Assisted Thoracic Surgery.Cureus · 2026
- Arterial-to-end-tidal carbon dioxide gradient as a risk marker for recorded 90-day mortality in intracranial neurosurgery: a retrospective INSPIRE cohort study of patients with early blood gas monitoring.Journal of clinical anesthesia · 2026
- Effect of different CO₂ insufflation pressures on endotracheal cuff pressure, airway pressures, and postoperative respiratory complications during robotic radical prostatectomy: a randomized controlled trial.Journal of robotic surgery · 2026
- Higher end-tidal CO2 levels and hypercapnia risk during transoral endoscopic thyroidectomy vestibular approach (TOETVA) compared with the bilateral axillo-breast approach (BABA): a retrospective cohort study.Surgical endoscopy · 2026