Journal of robotic surgery

Effect of different CO₂ insufflation pressures on endotracheal cuff pressure, airway pressures, and postoperative respiratory complications during robotic radical prostatectomy: a randomized controlled trial.

Fidan Aygün, Ilayda Kalyoncu Karahan

Department of Anaesthesiology and Reanimation, Bakırköy Dr. Sadi Konuk Training and Research Hospital, Istanbul, Turkey. · Department of Anaesthesiology and Reanimation, Bakırköy Dr. Sadi Konuk Training and Research Hospital, Istanbul, Turkey. ilaydaakalyoncu@gmail.com.

Randomised

Key points

From the paper's conclusion
  • Within the 10-15 mmHg range, CO₂ insufflation pressure had no detectable dose-dependent effect on ETT cuff pressure during RARP; between-group differences larger than approximately 3.5 cmH₂O are unlikely.

Abstract

Robot assisted radical prostatectomy (RARP) requires prolonged pneumoperitoneum and steep Trendelenburg positioning, which raise airway pressures that may be transmitted to the endotracheal tube (ETT) cuff. We investigated whether the level of carbon dioxide (CO₂) insufflation pressure affects ETT cuff pressure during RARP. In this single centre, three arm, parallel group randomized controlled trial, 90 patient undergoing elective RARP were randomly assigned to an intraabdominal CO₂ insufflation pressure of 10, 12, or 15 mmHg (30 per group) under a standardized anaesthetic. Cuff pressure was measured with a manometer and readjusted to baseline at eleven perioperative time points; peak and plateau airway pressures, end-tidal CO₂, and postoperative sore throat, hoarseness, and cough (1, 24, and 72 h) were also recorded. The primary outcome was the time-averaged cuff pressure during the pneumoperitoneum and steep Trendelenburg phase. Time averaged cuff pressure did not differ among the 10, 12, and 15 mmHg groups (30.3 ± 3.7, 28.7 ± 2.2, and 29.9 ± 2.8 cmH₂O; P = 0.089; pairwise differences - 1.6 to + 1.3 cmH₂O, all 95% confidence intervals within ± 3.5 cmH₂O), nor did peak cuff pressure, airway pressures, or end-tidal CO₂ at any time point. Between consecutive measurements, cuff and peak airway pressures rose and fell together at insufflation, Trendelenburg positioning, and return to supine, but the size of a patient's airway-pressure change did not predict the cuff-pressure change. Postoperative respiratory symptoms were infrequent and similar between groups. Within all groups, cuff and airway pressures changed significantly over time. Within the 10-15 mmHg range, CO₂ insufflation pressure had no detectable dose-dependent effect on ETT cuff pressure during RARP; between-group differences larger than approximately 3.5 cmH₂O are unlikely. Cuff pressure nonetheless frequently exceeded the recommended range, supporting regular manometric monitoring during surgery.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Effect of different CO₂ insufflation pressures on endotracheal cuff pressure, airway pressures, and postoperative respiratory complications during robotic radical prostatectomy: a randomized controlled trial — Science Skim