Surgical Technique - The "Derriere View" for Evaluation of Guidewire Position in Cephalomedullary Nailing of Intertrochanteric Femur Fractures.
Omar El Dishish, Qing Hang Tan, Amirzeb Aurangzeb, Kevin Ho Yin Wong, Andy Yeo
Orthopaedic Surgery, Changi General Hospital, Singapore, SGP.
Key points
From the paper's conclusion- This technical report describes the Derriere view, an additional intraoperative fluoroscopic projection applied during cephalomedullary nailing of intertrochanteric fractures with the targeting jig and instrumentation in situ.
Abstract
Intertrochanteric (IT) hip fractures are common in the elderly and are frequently treated with cephalomedullary nailing. Despite advances in implant design, fixation failure, such as cut-out or cut-through, remains a concern, often related to suboptimal implant positioning and limited intraoperative visualization of the femoral neck cortex. This technical report describes the Derriere view, an additional intraoperative fluoroscopic projection applied during cephalomedullary nailing of intertrochanteric fractures with the targeting jig and instrumentation in situ. The view is obtained by rotating the C-arm approximately 40° cranially from the standard lateral position and is intended to provide additional visualization of the posterior femoral neck cortex when this is inadequately delineated on conventional projections. The technique has been routinely used at our center as an adjunct to standard fluoroscopic views, particularly when conventional anteroposterior and lateral projections provide inadequate visualization of the posterior cortex. This additional projection may facilitate intraoperative identification of guidewires positioned close to the posterior cortex, allowing timely repositioning before definitive implant placement. It may be particularly useful in anatomically complex or comminuted fractures where reduction is suboptimal. The Derriere view is a simple adjunct to standard fluoroscopic imaging that may improve posterior cortical visualization during IT fracture fixation. Further prospective studies are required to determine its reproducibility, clinical effectiveness, and potential to reduce implant malposition and associated complications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reverse Obliquity Intertrochanteric Hip Fractures: A Technique Guide for Using a Blocking Screw to Enhance Fixation.Cureus · 2026
- Intraoperative Guidewire Breakage During Proximal Femoral Nailing Managed Through Direct Anterior Approach: A Case Report and Review of Literature.JBJS case connector · 2026
- Posterior Acetabular Wall Fracture Mimicking a Subcapital Femoral Neck Fracture on Plain Radiographs: A Diagnostic Pitfall and the Role of Intraoperative Fluoroscopy: A Case Report.Journal of orthopaedic case reports · 2026
- A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region.PloS one · 2026
- Proximal femoral nail antirotation complication presenting as isolated barrel migration after intertrochanteric fracture fixation.BMJ case reports · 2026
- Retrograde gearshift pedicle probe-assisted reduction of displaced superior pubic rami fractures: A technical note.Injury · 2026