Retrograde gearshift pedicle probe-assisted reduction of displaced superior pubic rami fractures: A technical note.
Justin E Hellwinkel, Joost L van Jaarsveld, John E Duldner, Andres Medina Paya, Okan Aslanturk, Cyril P Mauffrey, Adam M Schlauch
Center for Orthopedic Research and Education (CORE), Department of Orthopedic Surgery, Denver Health Medical Center, Denver, Colorado, USA; Department of Orthopedic Surgery, University of Colorado School of Medicine, Aurora, Colorado, USA. Electronic address: justin.hellwinkel@dhha.org. · Center for Orthopedic Research and Education (CORE), Department of Orthopedic Surgery, Denver Health Medical Center, Denver, Colorado, USA. Electronic address: joost.vanjaarsveld@ru.nl.
Key points
From the paper's conclusion- The curved gearshift pedicle probe is a rigid intramedullary reduction aid capable of multiplanar fragment manipulation and restoration of superior pubic ramus corridor while preserving independent selection of definitive fixation.
Abstract
Percutaneous fixation of superior pubic ramus fractures relies on establishment of safe corridors. Rotational and multiplanar deformity due to fracture disrupts the corridors and percutaneous or open reduction of these fractures is challenging. Retrograde insertion of a curved gearshift pedicle probe allows the surgeon to create a joystick to affect translation, rotation and angulation with a single instrument to restore the superior pubic ramus corridor and allow passage of an antegrade wire or screw. Following corridor restoration, reduction was captured antegrade, while definitive implant type and trajectory were selected independently according to fracture and osseous corridor morphology. Three displaced superior pubic ramus fractures were treated using this technique including mid-ramus, high ramus and segmental fractures with translational and rotational components. The probe was effectively used to de-rotate and reduce the fractures to allow for safe insertion of internal fixation with full containment and no complications. The curved gearshift pedicle probe is a rigid intramedullary reduction aid capable of multiplanar fragment manipulation and restoration of superior pubic ramus corridor while preserving independent selection of definitive fixation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trans-symphyseal fixation for complex anterior pelvic fractures: a novel technique guide and case seriesOTA International The Open Access Journal of Orthopaedic Trauma · 2026
- Reverse Obliquity Intertrochanteric Hip Fractures: A Technique Guide for Using a Blocking Screw to Enhance Fixation.Cureus · 2026
- Staged Reduction and Combined Anterior and Posterior Minimally Invasive Fixation for a Highly Unstable Open-Book Pelvic Ring Fracture: A Case Report.Cureus · 2026
- Surgical Technique - The "Derriere View" for Evaluation of Guidewire Position in Cephalomedullary Nailing of Intertrochanteric Femur Fractures.Cureus · 2026
- EP9.11 Anterior Periosteal Flap Elevation to aid Reduction and reduce retinacular tension in Pipkin I/II Femoral Head FracturesJournal of Hip Preservation Surgery · 2026
- Surgical management of severely displaced IPRF: operative technique, indications, and preliminary clinical outcomes.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026