Reliability and criterion validity of abductor hallucis muscle volume measurements using ultrasound and MRI by assessors with limited image analysis experience.
Jacob B Willes, Emma Robinson, Joshua K Sponbeck, Derek A Swanson, Dallin C Swanson, Austin G Goodrich, Steven P Allen, A Wayne Johnson
Department of Exercise Sciences, Brigham Young University, Provo, Utah, United States of America. · Department of Athletic Training and Occupational Therapy, Weber State University, Ogden, Utah, United States of America.
Key points
From the paper's conclusion- Conclusion US-derived ABDH volume measurements demonstrated high intrarater reliability and statistical equivalence to MRI within the ± 10% margin.
Abstract
PURPOSE: The abductor hallucis (ABDH) contributes to foot function and mobility, which can influence quality of life, making accurate assessment of muscle volume important. While magnetic resonance imaging (MRI) is often considered to be the reference standard of medical imaging, ultrasound (US) provides a cost-effective, rapid and dynamic way of assessing muscle size and function. This study aimed to evaluate the criterion validity and intrarater reliability of US-derived ABDH muscle volume measurements compared with MRI when image analysis was performed by assessors with limited experience. METHODS: Us And MRI were employed to measure the right and left ABDH muscle volume involving 22 participants (females = 12; males = 10). Following exclusions, 37 feet were available for analysis, with 36 complete MRI-US observations. Muscle volume of the ABDH was calculated across the muscle belly every 0.5 cm both manually by utilizing a truncated cone (TC) formula and with a semi-automated tool in the OsiriX (OX) software. Intrarater reliability was assessed using intraclass correlation coefficients (ICC), standard error of measurement (SEm), and minimal detectable change (MDC). Criterion validity was evaluated using Pearson correlations, Bland-Altman analyses, and two one-sided tests (TOST) with a determined ±10% equivalence margin. RESULTS: Side-specific intrarater reliability was high across methods (ICC(3,1) = 0.932-0.997), with SEm values of 0.251-0.709 cm³ and relative MDC values of 4.48%-12.95%. Very strong associations were observed among methods (r = 0.906-0.995). Bland-Altman limits-of-agreement half-widths were 6.52%-9.84% for MRI-MRI and 17.86%-27.35% for MRI-US comparisons. All three method comparisons met the ± 10% equivalence criterion. CONCLUSION: US-derived ABDH volume measurements demonstrated high intrarater reliability and statistical equivalence to MRI within the ± 10% margin. Although MRI-US comparisons showed greater individual-level variability than MRI-MRI comparisons, US may provide a practical alternative for assessing ABDH muscle volume when MRI is impractical.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound Evaluation of the Abductor Hallucis Muscle in Youth: A Reliability StudyJournal of Foot and Ankle Research · 2026
- MuscleExpert: a semi-automated tool delivering ImageJ-comparable measurements of muscle thickness, area, and quality.PeerJ · 2026
- Validity of Freehand 3-D Ultrasound for Skeletal Muscle Volume Assessment: A Systematic Review and Meta-Analysis.Ultrasound in medicine & biology · 2026
- Reliability and measurement error of hip abductor muscle strength using a hand-held dynamometer in healthy adults.Journal of physical therapy science · 2026
- Measurement Reliability and Trial-Sampling Effects in Ultrasound Assessment of Abdominal Muscle Thickness During the Active Straight Leg RaiseDiagnostics · 2026
- Muscle ultrasound for nutrition assessment: Practical clinical protocols.Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition · 2026